HomeMy WebLinkAboutTerracon - 12/11/2018 (6)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0537 Service Date: 11/09/18 2501 E Loop 820 N Report Date: 12/11/18 Revision 2 - 28 -day results Fort Worth, TX 76118-6978 Task: Parkine Garace 817-268-8600 Ree No: F-3272 Client Project Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Material Information Sample Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 0900 Truck No.: 6222 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Plant: 110 Ticket No.: 11033239 Result Specification 9 5-9 6.0 3-6 62 46 138.8 Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: Laboratory Test Data Strength Fracture Tested Age at Maximum Set Specimen Avg Diam. Area Date Date Test Load No. ID (in) (sq in) Received Tested (days) (lbs) 1 A 4.00 12.57 11/10/18 11/12/18 3 44,810 1 B 4.00 12.57 11/10/18 11/16/18 7 60,150 1 C 4.00 12.57 11/10/18 12/07/18 28 72,000 1 D 4.00 12.57 11/10/18 12/07/18 28 72,120 1 E 4.00 12.57 11/10/18 12/07/18 28 75,790 Average (28 days) 1 F 11/10/18 Hold Initial Cure: Outside Final Cure: Moist Room 11/09/18 Sample Time: 0937 Christopher Thompson Clear 9/45 Batch Size (cy): 9 Pump Grid Line P5.5/16 Elevated Deck, Level 6, Pour 1B, Grid Line P5.5 -P7.5/16-17 Compressive Strength Fracture Tested (psi) Type By 3,570 4 4,790 5 5,730 4 5,740 4 6,030 3 5,830 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Christopher Thompson Reported To: Contractor: Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Page Irerracon Report Number: 95181011.0537 Service Date: 11/09/18 2501 E Loop 820 N Report Date: 12/11/18 Revision 2 - 28 -day results Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) JQ Engineering, Mike Oler (1) Manhattan Construction Company, Ben Jensen (1) Manhattan Construction Company, Chase Pritchard (1) Manhattan Construction Company, Daniel Rideau (1) Manhattan Construction Company, David Saiter (1) Manhattan Construction Company, Frederick Moore (1) Manhattan Construction Company, Klint Robertson (1) Manhattan Construction Company, Matthew Powell (1) Manhattan Construction Company, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva