Loading...
HomeMy WebLinkAboutTerracon - 12/11/2018 (5)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0540 Service Date: 11/10/18 2501 E Loop 820 N Report Date: 12/11/18 Revision 2 - 28 -day results Fort Worth, TX 76118-6978 Task: Hotel 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 7,000 psi @ Mix ID: 9908 Supplier: Argos Batch Time: 0829 Truck No.: 6270 Field Test Data Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information 28 days Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Plant: 110 Ticket No.: 11033280 Test Result Specification Slump (in): 10 1/2 * 6-9 Air Content (%): 1.2 0-3 Concrete Temp. (F): 62 50-95 Ambient Temp. (F): 38 4.00 Plastic Unit Wt. (pcf): 149.7 C Yield (Cu. Yds.): * = Field Test Results do not meet project specifications. Laboratory Test Data Set Specimen Avg Diam. Area No. ID (in) (sq in) 1 A 4.00 12.57 1 B 4.00 12.57 1 C 4.00 12.57 1 D 4.00 12.57 Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 11/10/18 Sample Time: 0930 Adam Wood Partly Cloudy 9 Batch Size (cy): 9 Bucket & lift 0 0 Column E.8/12 E/6 Elevator All pit walls, 1 st to 2nd level Columns E.8/12, E.2/12, G.6/12, G.6/13 Compressive Strength Age at Maximum Date Date Test Load Received Tested (days) (lbs) 11/17/18 7 116,320 12/08/18 28 142,770 12/08/18 28 145,140 12/08/18 28 140,940 Average (28 days) 11/10/18 Sample Time: 0930 Adam Wood Partly Cloudy 9 Batch Size (cy): 9 Bucket & lift 0 0 Column E.8/12 E/6 Elevator All pit walls, 1 st to 2nd level Columns E.8/12, E.2/12, G.6/12, G.6/13 Compressive Strength Fracture Tested (psi) Type By 9,260 5 11,360 3 11,550 2 11,220 4 11,380 1 E Hold Initial Cure: Outside Final Cure: Moist Room Comments: Average compressive strength of 28 day cylinders complies with the specified strength. David Saiter with Manhattan was notified of the excessive slump. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Adam Wood Reported To: David w/ Manhattan Contractor: Manhattan Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Paae Report Number: 95181011.0540 Service Date: 11/10/18 Report Date: 12/11/18 Revision 2 - 28 -day results Task: Hotel Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) JQ Engineering, Mike Oler (1) Manhattan Construction Company, Ben Jensen (1) Manhattan Construction Company, Chase Pritchard (1) Manhattan Construction Company, Daniel Rideau (1) Manhattan Construction Company, David Saiter (1) Manhattan Construction Company, Frederick Moore (1) Manhattan Construction Company, Klint Robertson (1) Manhattan Construction Company, Matthew Powell (1) Manhattan Construction Company, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva Irerracon 2501 E Loop 820 N Fort Worth, TX 76118-6978 817-268-8600