Loading...
HomeMy WebLinkAboutTerracon - 12/5/2018 (3)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0562 Service Date: 11/27/18 2501 E Loop 820 N Report Date: 12/05/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 0800 Plant: Truck No.: 1737 Ticket No.: 12334539 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 9 5-9 4.5 3-6 55 35 147.2 Laboratory Test Data Set Specimen Avg Diam. Area Date Date No. ID (in) (sq in) Received Tested Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information A Sample Date: 11/27/18 Sample Time: 0830 Sampled By: Conrado Molina Weather Conditions: Clear Accumulative Yards: 9 Batch Size (cy): 9 Placement Method: Pump Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Garage Upturn 6th, P3/15 Placement Location: Garage Upturn Beam 6th P3 -P4/15, 28 Garage Columns 6th P4/17, P7/15, D P8/15, P7/18, Bumper Wall P4 -P6/18, 12.57 Garage Bumper Wall P1 -P2/15, 12/25/18 P1 -P3/18 Age at Maximum Compressive Test Load Strength Fracture Tested (days) (lbs) (psi) Type By 1 A 4.00 12.57 11/28/18 11/29/18 2 48,160 3,830 2 1 B 4.00 12.57 11/28/18 12/04/18 7 71,350 5,680 4 1 C 4.00 12.57 11/28/18 12/25/18 28 1 D 4.00 12.57 11/28/18 12/25/18 28 1 E 4.00 12.57 11/28/18 12/25/18 28 1 F 11/28/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Conrado Molina Reported To: David w/ Manhattan Contractor: Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0562 Service Date: 11/27/18 2501 E Loop 820 N Report Date: 12/05/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 0900 Plant: Truck No.: 6027 Ticket No.: 11124791 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 9 5-9 4.9 3-6 60 50 146.0 Laboratory Test Data Set Specimen Avg Diam. Area Date Date No. ID (in) (sq in) Received Tested Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information A Sample Date: 11/27/18 Sample Time: 0930 Sampled By: Conrado Molina Weather Conditions: Clear Accumulative Yards: 81 Batch Size (cy): 9 Placement Method: Pump Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: 6th Upturn Beam, P6/18 Placement Location: Garage Upturn Beam 6th P3 -P4/15, 4.00 Garage Columns 6th P4/17, P7/15, 11/28/18 P8/15, P7/18, Bumper Wall P4 -P6/18, 7 Garage Bumper Wall P1 -P2/15, 4,550 3 P1 -P3/18 Age at Maximum Compressive Test Load Strength Fracture Tested (days) (lbs) (psi) Type By 2 A 4.00 12.57 11/28/18 11/29/18 2 33,740 2,680 5 2 B 4.00 12.57 11/28/18 11/30/18 3 43,850 3,490 4 2 C 4.00 12.57 11/28/18 12/04/18 7 57,210 4,550 3 2 D 4.00 12.57 11/28/18 12/25/18 28 2 E 4.00 12.57 11/28/18 12/25/18 28 2 F 4.00 12.57 11/28/18 12/25/18 28 Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Conrado Molina Reported To: David w/ Manhattan Contractor: Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0562 Service Date: 11/27/18 2501 E Loop 820 N Report Date: 12/05/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 1200 Plant: Truck No.: 5114 Ticket No.: 12334578 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 9 5-9 4.0 3-6 60 50 146.4 Laboratory Test Data Set Specimen Avg Diam. Area Date Date No. ID (in) (sq in) Received Tested Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information A Sample Date: 11/27/18 Sample Time: 1230 Sampled By: Conrado Molina Weather Conditions: Clear Accumulative Yards: 9 Batch Size (cy): 9 Placement Method: Pump Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Garage Bumper Wall, P1 /15 Placement Location: Garage Upturn Beam 6th P3 -P4/15, 28 Garage Columns 6th P4/17, P7/15, D P8/15, P7/18, Bumper Wall P4 -P6/18, 12.57 Garage Bumper Wall P1 -P2/15, 12/25/18 P1 -P3/18 Age at Maximum Compressive Test Load Strength Fracture Tested (days) (lbs) (psi) Type By 3 A 4.00 12.57 11/28/18 12/03/18 6 61,490 4,890 4 3 B 4.00 12.57 11/28/18 12/04/18 7 60,580 4,820 5 3 C 4.00 12.57 11/28/18 12/25/18 28 3 D 4.00 12.57 11/28/18 12/25/18 28 3 E 4.00 12.57 11/28/18 12/25/18 28 3 F 11/28/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Conrado Molina Reported To: David w/ Manhattan Contractor: Report Distribution: See attached distribution list. Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 3 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0562 Service Date: 11/27/18 2501 E Loop 820 N Report Date: 12/05/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Material Information Specified Strength: 5,000 psi @ 28 days Mix ID: 9041 Supplier: Argos Batch Time: 1400 Plant: Truck No.: 6283 Ticket No.: 12334590 Field Test Data Test Slump (in): Air Content (%): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Result Specification 6 5-9 4.0 3-6 60 50 147.2 Set Specimen Avg Diam. Area Date Date No. ID (in) (sq in) Received Tested Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Sample Information A Sample Date: 11/27/18 Sample Time: 1430 Sampled By: Conrado Molina Weather Conditions: Clear Accumulative Yards: 9 Batch Size (cy): 9 Placement Method: Bucket & lift Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Garage Columns, 6th P4/17 Placement Location: Garage Upturn Beam 6th P3 -P4/15, 28 Garage Columns 6th P4/17, P7/15, D P8/15, P7/18, Bumper Wall P4 -P6/18, 12.57 Garage Bumper Wall P1 -P2/15, 12/25/18 P1 -P3/18 Age at Maximum Compressive Test Load Strength Fracture Tested (days) (lbs) (psi) Type By 4 A 4.00 12.57 11/28/18 11/29/18 2 35,700 2,840 4 4 B 4.00 12.57 11/28/18 12/04/18 7 63,900 5,090 2 4 C 4.00 12.57 11/28/18 12/25/18 28 4 D 4.00 12.57 11/28/18 12/25/18 28 4 E 4.00 12.57 11/28/18 12/25/18 28 4 F 11/28/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Conrado Molina Reported To: David w/ Manhattan Contractor: Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 4 of 4 Distribution Page Irerracon Report Number: 95181011.0562 Service Date: 11/27/18 2501 E Loop 820 N Report Date: 12/05/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) JQ Engineering, Mike Oler (1) Manhattan Construction Company, Ben Jensen (1) Manhattan Construction Company, Chase Pritchard (1) Manhattan Construction Company, Daniel Rideau (1) Manhattan Construction Company, David Saiter (1) Manhattan Construction Company, Frederick Moore (1) Manhattan Construction Company, Klint Robertson (1) Manhattan Construction Company, Matthew Powell (1) Manhattan Construction Company, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva