HomeMy WebLinkAboutTerracon - 12/18/2018 (10)CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 95181011.0582 Service Date: 12/11/18 2501 E Loop 820 N Report Date: 12/18/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Reg No: F-3272 Client Coury Hospitality Attn: Mark Brooks 7134 S Yale, Ste 400 Tulsa, OK 74136 Specimen Project Grapevine Main Phase 1 815 South Main Street Grapevine, TX 76051 Project Number: 95181011 Area Material Information Date Sample Information Strength Fracture Tested Specified Strength: 5,000 psi @ 28 days Sample Date: 12/11/18 Sample Time: 1300 Received Tested Sampled By: Daniel Blocker Mix ID: 9041 A Weather Conditions: Clear Supplier: Argos 12/17/18 Accumulative Yards: 6 Batch Size (cy): 6 Batch Time: 1200 Plant: 123 Placement Method: Pump Truck No.: 5114 Ticket No.: 12335222 Water Added Before (gal): Field Test Data C Water Added After (gal): 12.57 12/12/18 01/08/19 Sample Location: Pour Strip, Grid Line P7.5/15.2 Test Result Specification Placement Location: Level 4, Pour Strips, Grid Line Slump (in): 8 1/2 5-9 28 P7.5/15-16, P7.5/16-17 Air Content (%): 6.0 3-6 4.00 12.57 Concrete Temp. (F): 57 28 Ambient Temp. (F): 50 Plastic Unit Wt. (pcf): Hold Yield (Cu. Yds.): 43.4 Laboratory Test Data Age at Maximum Compressive Set Specimen Avg Diam. Area Date Date Test Load Strength Fracture Tested No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type By 1 A 4.00 12.57 12/12/18 12/17/18 6 64,780 5,160 2 1 B 4.00 12.57 12/12/18 12/18/18 7 1 C 4.00 12.57 12/12/18 01/08/19 28 1 D 4.00 12.57 12/12/18 01/08/19 28 1 E 4.00 12.57 12/12/18 01/08/19 28 1 F 12/12/18 Hold Initial Cure: Outside Final Cure: Moist Room Comments: Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Daniel Blocker Reported To: Contractor: Report Distribution: See attached distribution list. Reviewed By: Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. cx000t, 11-16-12, xev.6 Page 1 of 1 Distribution Page Irerracon Report Number: 95181011.0582 Service Date: 12/11/18 2501 E Loop 820 N Report Date: 12/18/18 Fort Worth, TX 76118-6978 Task: Parking Garage 817-268-8600 Distribution List (1) Coury Hospitality, Mark Brooks (1) AECC Inc, Lee Ledet (1) ArchiTexas, Michael Karnowski (1) City of Grapevine TX, Curtis A Bergthold (1) City of Grapevine TX, Hans Strayer (1) City of Grapevine TX, Paul M Lee (1) City of Grapevine TX, Scott Williams (1) City of Grapevine TX, sbatte@grapevinetexas.gov (1) JQ Engineering, Mike Oler (1) Manhattan Construction Company, Ben Jensen (1) Manhattan Construction Company, Chase Pritchard (1) Manhattan Construction Company, Daniel Rideau (1) Manhattan Construction Company, David Saiter (1) Manhattan Construction Company, Frederick Moore (1) Manhattan Construction Company, Klint Robertson (1) Manhattan Construction Company, Matthew Powell (1) Manhattan Construction Company, Robert Montgomery (1) Walker Consultants, Martha M. Villanueva