Loading...
HomeMy WebLinkAboutCA2019-02GRA VINE T E X A S r 31 January 2019 A Future With A Past Jeffery Marshall IFR Foundation Repair, Inc. 5047 David Strickland Road, Suite #402 Fort Worth, Texas 76119 817 561-6501 RE: HISTORIC PRESERVATION COMMISSION CERTIFICATE OF APPROPRIATENESS #CA19-05 MILLICAN HOUSE, HISTORIC LANDMARK #HL1992-02 603 EAST WORTH STREET GRAPEVINE, TEXAS 76051 This letter confirms on January 31, 2019 the Historic Preservation Commission staff approved with conditions #CA19-05 for the property addressed 603 East Worth Street, legally described as Block 109, Lot 1 & 2, College Heights Addition, City of Grapevine Texas. The following was approved on this Certificate of Appropriateness: 1. Repair existing pier and beam foundation of the house including installing additional concrete supports, reset and re -shim the foundation as needed; 2. Install approximately 20 feet of support beams under center of house; as per the attached plan with the condition a permit be obtained from the Building Department. An approved Certificate of Appropriateness is not an approved building permit; a building permit his '/ is not required. Contact the City of Grapevine's Building Department at 817.410.3165 for fees and information regarding permits. Thank you, David Klempin Historic Preservation Officer wdk cc. Property Owner CA File THE CITY OF GRAPEVINE HISTORIC PRESERVATION • 636 South Main Street • Grapevine, Texas 76051 Phone 817/410-3556 - Fax 817/410-3038 RECEIVED P A! 15 nnVy CERTIFICATE OF APPROPRIA10 y, APPUCATiON Property Owner Name. Ad&ess & Rhone Number I Email: Ad f Tenarrt NametOosupancyMse of Work to Be Done MtA DrawJn J$lc�tChlea Attsdtod No 8kck L— Lot -1 Subd6ition C'O RCA1t P ht Attfccitod �rrerrt a Historic ,..hereby .hereby Ct3Ytlfy that this rnfixrn�ion rs to Me beat of my ✓;Tov&dge of d that the said woA- v0be da -he to �-nfprmvfj%�ku i0h * subrm -.sib herein iw compliance with file C4 Qf [;rpe+rrnf' �+'iYto�'iC Chre+�6y c1 CJ+d�n2r;ces tvrJ eOW&ftg APPROV PTW40ATE OF APPRUPR A:ENESS DOES WT CONSTTTUTE APPRO VA L OF OTHER REQUIRED SUIL 5712-0- oti x Print Name C3lirioe uSa �?�ifiVL'd- AAMov� mitt �iCw11�ItK1i:`o: Blatt X x swg ;w m;&,v ?U411 r 'T rte,-)) r �L r -- THIS IS t4OT A BUILLDHNG PERMIT. �/ U A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY ;NE DUiLDING DEPARTMENT BEFORE STARTING WORK. DELrffB TO: HISTORIC PRESERVATION DEPARTMENT OFFICE 817-410-35SC 636 SC►UTH MAIN STREET, GRAPEVINE- TEXAS 1rtw,'t v- Iw"I - Graft ein Account #: 05682266 Georeference: 7670-109-1 Property Location: 603 E WORTH ST Jurisdictions: 011 CITY OF GRAPEVINE 220 TARRANT COUNTY 906 GRAPEVINE-COLLEYVILLE ISD 224 TARRANT COUNTY HOSPITAL 225 TARRANT COUNTY COLLEGE TARRANT APPRAISAL DISTRICT 01/31/2019 Owner Information MEYER THERESA M 603 E WORTH ST GRAPEVINE, TX 76051 r f' 5 -Year Value History This information is intended for reference only and is subject to change. It may not accurately reflect the complete status of the account as actually carried in TAD'S datahase. Year Improvement Market Land Market Total Market Total Appraised 2019 $0 $0 $0 $0 2018 $121,224 $180,000 $301,224 $225,738 2017 $123,095 $180,000 $303,095 $205,216 2016 $222,479 $62,860 $285,339 $186,560 2015 $119,600 $50,000 $169,600 $169,600 A zero value indicates that the property record has not yet been completed for the indicated tax year t Appraised value may be less than market value due to state -mandated limitations on value increases Property Data Legal Description: COLLEGE HEIGHTS ADDITION- GRPVN Block 109 Lot 1 BLK 109 LTS 1 & 2 Deed Date: 07-31-2018 Instrument: D218172763 Year Built: 1920 Agent: None Notice Sent: Protest Deadline: State Code: A Residential SingleFamily Approximate Size : 1,852 Land Acres ♦ : 0.3142 Land Sqft ♦: 13,689 ttt Rounded ♦ This represents one of a hierarchy of possible values ranked in the following order: Recorded, Computed, System. Calculated Exemptions • HOMESTEAD GENERAL 11.13(b) Tarrant Appraisal District 12500 Handley-Ederville Road, Fort Worth, TX 76118-6982 817-284-0024 LANDMARKED Lo CAST ic)2-4-1 5Tk-6ET 4f4�--9-03 Fo-o,'-DAT►09 JZEioAI�L� CERTIFICATE OF APPROPRIATENESS CITY OF GRAPEVINE REDS PURSUAN TO A DATE�� SY L PA Tr ENT OF DEVELOPMENT SERVICES CONTACT BUILDING INSPECTIONS FOR PERMIT INFORMATION CROSSTOWN Reset and re -shim total understructure as needed using steel shims on existing concrete supports Adam A. Green, P.E. (FL & TX), MBA Tampa: (813) 702 -3398 1 Dallas/Ft. Worth (469) 751-7694 www. Crosstown Engineer_ ing.c A E C E i V E D Install additional concrete supports as needed using precast block and pads -56 2.5 -2.0 OF GRAPEVINE THIS DRAWING IS PROVIDED FOR PRELIMINARY PERMITTING PURPOSES ONLY AND IS A LIMITED PLAN 603 4.5 PURS Laundry ®ATE Kitchen /s►tb _ PAR NT OF O LOPMENT SERVICES 2.5 2.5 24 CONT BUILbING INSPECTIONS LOCATIONS SHOWN ON THIS MAP ARE APPROXIMATE. THE CONTRACTOR SHALL PROVIDE THE MEANS- EANS ERMIT INFORMATION AND-METHODS AND -METHODS OF THIS INSTALLATION. ADDITIONAL REPAIRS MAY BE REQUIRED UPON REVIEW OF THE 01/14/19 STRUCTURE BY CROSSTOWN ENGINEERING. Bath THIS IS A PROPOSED SCOPE OF WORK AND HAS NOT BEEN COMPLETED THEREFORE WE DO NOT CERTIFY Crosstown Engineering ANY EXISTING OR PROPOSED FOUNDATION REPAIR WORK ON THIS MAP AT THIS TIME. 2.0 •1.0 (F-15944) COMPLETED THEY MUST REQUEST AN ENGINEERING CERTIFICATE FOR THE SUBJECT FOUNDATION 3960 Park Ln a 2.2 -1.3 8.0 0.8 Master BR PC" 2.5 res 8.5 S Wood deck porch 4 JAN 15 an10 Install approximately 20 feet Outside of support beam using Access pressure -treated 2 x 6 x 2 Peek D -1.5 1.4 CERTIFICINTE OF APPROPRIATENESSZOOOor tv i,1r OF GRAPEVINE THIS DRAWING IS PROVIDED FOR PRELIMINARY PERMITTING PURPOSES ONLY AND IS A LIMITED PLAN 603 RELFA ►—© �� PURS TO ®ATE BY /s►tb _ PAR NT OF O LOPMENT SERVICES 2.5 2.5 4*611�vf' CONT BUILbING INSPECTIONS LOCATIONS SHOWN ON THIS MAP ARE APPROXIMATE. THE CONTRACTOR SHALL PROVIDE THE MEANS- EANS ERMIT INFORMATION FOR 6R 2 2.8 — 41 PLEASE NOTE: THIS DRAWING IS PROVIDED FOR PRELIMINARY PERMITTING PURPOSES ONLY AND IS A LIMITED PLAN 603 E Worth St, Grapevine, TX OF REPAIR. ADDITIONAL WORK MAYBE NEEDED ONCE THE FOUNDATION WORK HAS BEGUN BASED 76051 ON THE PERFORMANCE OF THIS LIMITED PLAN OF REPAIR. CROSSTOWN ENGINEERING HAS PROVIDED REVIEW OF THIS LIMITED PLAN OF REPAIR AND IT IS OUR OPINION THAT IT IS REASONABLE AND SAFE FOR THE STRUCTURE. IF INTERIOR PIERS ARE SHOWN ON THIS DRAWING THE CONTRACTOR WILL PLACE THEM BASED ON THE 4*611�vf' LOCATIONS OF GRADE BEAMS, PLUMBING LINES AND POST TENSION CABLES, THEREFORE, THE ............... . LOCATIONS SHOWN ON THIS MAP ARE APPROXIMATE. THE CONTRACTOR SHALL PROVIDE THE MEANS- EANS AND-METHODS AND -METHODS OF THIS INSTALLATION. ADDITIONAL REPAIRS MAY BE REQUIRED UPON REVIEW OF THE 01/14/19 STRUCTURE BY CROSSTOWN ENGINEERING. THIS IS A PROPOSED SCOPE OF WORK AND HAS NOT BEEN COMPLETED THEREFORE WE DO NOT CERTIFY Crosstown Engineering ANY EXISTING OR PROPOSED FOUNDATION REPAIR WORK ON THIS MAP AT THIS TIME. Texas Engineering Firm IF THE READER WOULD LIKE TO BE CERTAIN THAT ANY PROPOSED OR EXISTING REPAIRS HAVE BEEN (F-15944) COMPLETED THEY MUST REQUEST AN ENGINEERING CERTIFICATE FOR THE SUBJECT FOUNDATION 3960 Park Ln WORK FROM THE FOUNDATION REPAIR COMPANY. Dallas, TX 75220 Integrity Foundation Repair Co. Phone (817)561-6500 Fax (817)561-6503 ifrdfwl@yahoo.com INTEGRITY FOUNDATION REPAIR AGREEMENT Date: January 11, 2019 Owner: Steve Terri Wheeler. Owner's Mailing Address: Owner's Telephone Number: (Home) 817-705-5678 Project Address: 603 E Worth St Grapevine, TX 76051 DESCRIPTION AND COST OF REPAIR: 1. Exterior Work Pilings: Concrete Breakout 2. Interior Work Pilings: Special Provisions: no. Revision. no. no. Vacant (Work) REMIT PAYMENT • Integrity Foundation Repair Co. P.O.Box122778 Fort Worth, TX 76121 ti Note: homeowner has requested to try to get the house as square as possible, a 2-3 inch lift is suggested Install additional concrete supports as needed using precast block and pads Install approximately 20 feet of support beam using pressure -treated 2 x 6 x 2 Reset and re -shim total understructure as needed using steel shims on existing concrete supports Provide independent structural engineers report, city permit and final plumbing test. Complete leveling is not to be expected. Provide one year warranty on understructure adjustments. Note: There is a 5% fee added to all credit card transactions !AN 15 '910 Integrity Foundation Repair is not financially responsible for plumbing issues as a result of the lift. If double sewer cleanout is not detected during final plumbing test one will need to be installed for $500 at customers expense. With payment to be made as follows: ❑ Down Payment: Zero ✓❑ Balance due upon completion: $ 5,480 ❑ Other: The price does not include any cosmetic repairs, plumbing, caulking, mortar repair, door adjustments, framing adjustments, unless specified provisions. All material is guaranteed to be as specified, and the above work to be performed in accordance with the drawings and specifications submitted for above work and completed in a substantial workmanlike manner. Integrity Foundation Repair is not responsible for any plumbing issues or cosmetic damages as a result of the repairs preformed. Any alteration or deviation from the above specifications involving extra costs will be executed only upon written order, and will become an extra charge over and above the contract. NOTE: this contract may be withdrawn by Integrity Foundation Repair if not accepted within 14 days. The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payments will be made as outlined above. Proposal written by: Jeff Dutton 817-706-3430 Date Signature: Signature: GENERAL CONDITIONS AND WARRANTY UPON REQUEST