Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2019-02-06
AGENDA CITY OF GRAPEVINE SITE PLAN REVIEW COMMITTEE MEETING WEDNESDAY, FEBRUARY 6, 2019 AT 1:30 P.M. PLANNING AND ZONING CONFERENCE ROOM 2ND FLOOR 200 SOUTH MAIN STREET GRAPEVINE, TEXAS I. CALL TO ORDER II. NEW BUSINESS A. Site Plan Review Committee to consider a public hearing relative to Conditional Use Request CU19-05 addressed as 3001 Ira E. Woods Avenue, and consideration of same. III. MINUTES A. Site Plan Review Committee to consider the minutes of the November 7, 2018, regular meeting. IV. ADJOURNMENT IF YOU PLAN TO ATTEND THIS PUBLIC HEARING AND YOU HAVE A DISABILITY THAT REQUIRES SPECIAL ARRANGEMENTS AT THE MEETING, PLEASE CONTACT THE OFFICE OF DEVELOPMENT SERVICES AT (817) 410-3155 AT LEAST 24 HOURS IN ADVANCE. REASONABLE ACCOMMODATIONS WILL BE MADE TO ASSIST YOUR NEEDS. IN ACCORDANCE WITH TEXAS GOVERNMENT CODE, CHAPTER 551.001 et seq. ACTS OF THE 1993 TEXAS LEGISLATURE, THE SITE PLAN REVIEW COMMITTEE MEETING AGENDA WAS PREPARED AND POSTED ON THIS THE 1ST DAY OF FEBRUARY 2019 AT 5:00 P.M. ALBERT L. TRIPLETT, JR PLANNER II DEVELOPMENT SERVICES TO: SITE PLAN REVIEW COMMITTEE MEMBERS DATE: FEBRUARY 6, 2019 SUBJECT: CONDITIONAL USE REQUEST CU19-05, LOT 1A, BLOCK 1, EDUCATION CENTER ADDITIONA NO. 3 RECOMMENDATION Staff recommends the Site Plan Review Committee consider Site Plan SP1 7-14 administratively approved on July 6, 2017 to allow for renovations to the Mustang - Panther Stadium, specifically to allow for an archway sign, and take any other action necessary. BACKGROUND INFORMATION Site Plan SP17-14 was administratively approved on July 6, 2017 to allow for renovations to the Mustang -Panther football stadium. The renovations included elevation changes throughout, including a new home side arched entry and archway sign. Based upon the type of sign and placement, staff has determined that the archway sign was approved in error. With this request the applicant proposes installing a two and one-half foot, 79.15 -square foot internally illuminated archway sign attached to the brick columns above the home side arched entrance of the stadium. The overall height of the sign when placed atop the entry columns is 19 -feet. No additional changes are proposed. O:\ CU\CU19-05.4sprc / / i ,k / - r X i / AA- <i�t'�`1A Ai N 8274'52' l X� �J X ,, ice. it y i i / N 8 ' " E 292.40' 711 1 0 �c 9 �/li —W r I 0 P�Lt9vNG � A AREA � f ; I i� 4 TARRANT COONTY MAPSCO F2&V VICINITY MAP (NOT TO SCALE) 0 30 60 120 '.80 GRAPHIC SCALE IN FEET L_ E= I=> BOLLARD ELECTRIC METER POWER POLE `0 LIGHT STANDARD WATER METER WATER VALVE '< IRRIGATION CONTROL VALVE �4 FIRE HYDRANT 3 CLEANOUT w�Qo MANHOLE TRAFFIC SIGNAL CONTROL. TRAFFIC SIGNAL POLE D TELEPHONE BOX FLOOD LIGHT FLAG POLE v>- TRAFFIC SIGN 1/2 -MCH IRON ROD IRS W/"PACHECH KOCH" CAP SET (C.M.) CONTROLLING MONUMENT �— — — — PROPERTY LINE FENCE FIRE LANE x • PROPOSED FENCE GRADE BREAK PROPOSED WALK y / _-' o- 1!!� 1' -�\ jf REFER TO LANDSCAPE SHEETS I 'Sr / � I LIMITS � ' TRAFFIC DIRECTION NOTE: TRAFFIC DIRECTION ARROWS ARE FOR •' ^�" ._ " t'1 !.. ` PROPOSED f — INFORMA710NA1 PURPOSES ONLY AND E BUILDILNG A- — — — _ � SHALL NOT 8E INSTALLED. r Y /, AREA 3 -+ AREA 4 = AREA b� _ r � yt f CopyigMs 2117, Nutkabe &AmWd1 ,Im. mi q n di Q W � tj J Q �V)U) co 00 X OF- W 0 W > Q O W W W EL W Z Z — �cl)�M� C rn .c IVR cgg r• 3S m t- {L .c � H IL Vex ro%1 3 • I Y'"' � x ro - � T 'I I � - I ', EAWFHD A�CNADWK9C � d doi ca 's' Loam : o a _ `}� � � .5z ) t, 'off o C GI OF GRAPE'ANE C0 % / r _ RE�i�EVECOMMITTEE n yv` ``1<!/,(I! �--,;.,- ..i !% ''moi---' DErNIED ci 67 -� ANG D PNJS'D OFIDI � SCE AREA B — �, _ s �" �C�T AREA 8 J \ �I k b e s w AREA T.s .. PLAT N-1 THE SEALAPPEARING ON THS DOCUMENT WAS AUiiRXi® RY EDwARo A CNADWCR, PL 109771 ON 03/17/2017. ALTERATION OF A SEALED DOCUMENT MTNWT PROPER NOTFICATION TO THE REEPONSIRIE ENGINEER IS AN OFFENSE UNDER THE TEXAS f ENGINEERING PRACTICE ACT. SITE PLAN CITY OF GRAPEVINE APPROVED APPROVAL DOES NOT AUTHORIZE ANY WORK IN CONFLICT WITH ANY CODES OR ORDINANCES. HUCkabee SITE PLAN PACKAGE A sn.0t No. s. s U, FY CF GRAPE"'HNE C,-= t" N C-la.:if'E" Ci®i`efd fit / [ LG �A : q' � tirN, Ir"D r� c ' 'i7 r� � s c s.. Am /--S ILLUMINATED LETTERS LED DETAILS °SNOT TO SCALE RACEWAY AND LETTERS PAINTED WHITE WITH WHITE LEXAN FACES AND TRIM CAP 4.5" X 7.0" X 1.0" Thick Raceway behind Letters Connected w/ .5" Conduit Nem. Mustang Panther Stadium Desuipli : UUM. LOGO SIGN M Ste Lee Lewis Construction Location: 3001 Ira E. woods Ave Grapevine, TX 76051 Main Entrance DISCLAIMER This is an original unpublished drawing created by The Router Room LLC. It is submitted for your personal use in conjunction with a project being planned for you by The Router Room LLC, and shall not be reproduced, used by or disclosed to any firm or corporation for any purpose whatsoever without written permission. Designer I Date FeAsion Description UL Certified Manufacturer Assembled per UL Standards CLIENT E SHEET ©ILLUMINATED LETTERS LED DETAILS 018 NOT TO SCALE LETTER RETURNS, BACKS AND RACEWAY PAINTED WHITE, WHITE LEXAN FACES WITH WHITE TRIM CAP. 31'-8" 124.1 " 1 115" 1 114.1 " Aluminum raceway 1/2" Conduit Aluminum Raceway 1/2" Conduit Aluminum Haceway 4.5" X 7.0" x .10" 4.5" X 7,0" x.10" 4.5" X 7.0" x .10" Date: Project Nave: Mustang Panther Stadium tee: ILLUM. LOGO SIGN Drawn: .�b�e Lee Lewis Construction 3001 Ira E. Woods Ave Grapevine, TX 76051 DISCLAIMER This is am, original unpublished drawing created by The Router Rva rn LLC. It is submitted for your personal use in conjrm titin with a project being planned for you by The Router R¢mst LLC, and shall not be reproduced, used by or disctcrse to any firm or corporation for any purpose whatsoever without written permission. Designer I Date Rwision Description T W 0 0 1 UL Certified Manufacturer Assembled per UL Standards r ::_iC�: �'{ C lip Lds ltIED ,sem �' a"ad.n'at arae 'c.av ,x r UTY CFOPYis U t € m (g, C'fi f_ la e Em- e.wk P x m3 ..✓ mve �' D;,7'= PLA't 71 --- ®ILLUMINATED LETTERS /LED SECTION DETAIL of S NOT TO SCALE SIDE VIEW OF 30.0" TALL LETTERS & RACEWAY TwIfir D%e: S.Z Dravn: All CUstom ,5lignage files 1/8" White Lexan w/ 1" White Trim Cap Name: Mustang Panther Stadium Dew' ILLUM. LOGO SIGN ,bb Ste Location: Lee Lewis Construction 3001 Ira E. Woods Ave Grapevine, TX 76051 Mechanical Fasteners 3" F7 DISCLAIMER This is an original unpublished drawing created by The Router Room LLC. It is submitted for your personal use in conjunction with a project being planned for you by The Router Room LLC, and shall not be reproduced, used by or disclosed to any firm or corporation for any purpose whatsoever without written permission. � Backs Painted White Channel Letters ninum Returns k Aluminum Cover ck Aluminum Back Plate Aluminum Raceway 4.5" X 7.0" X .10" Thick LED Transformer Steel Tube 8" X 8" X 1.0" Thick Wall Designer ! Dale Revision Description UL Certified Manufacturer Assembled per UL Standards CUBIT ! SHEET a SIGN FACE / FRAME DESIGNED BY OTHERS (NOT PART OF THIS SEAL) 7" x 4 1/2" RACEWAY MOUNTED ON TOP OF SUPPORT TUBE FASTENERS FROM SIGN TO MOUNTING TUBES PER TABLE w! MIN. 4" SPACING EXISTING 8" x 8" x 1" THICK STEEL TUBE BY OTHERS ;NOT PART OF THIS SEAL) 2015 INTERNATIONAL refASCE7-10 ca.o 54 t z i.I bun co.r sqT SIGN INSTALLER 1• verity (sq.tt.) (tlusn, raceway, or pin) (solid area or letters) Il, Normal hazard to human life; III, Substantial hazard to human Raceway Raceway Raceway 2. Select fastener for wall structure. Basic Wind Speed, Ultimate, mph, from ASCE7-10, Fig26.5-1A, (Letters) (Letters) (Letters) INSTRUCTIONS 3. Evenly space fasteners over whole sign area. Wind Exposure C, No unobstructed area within 120Dft; Wind Exposure D, Unobstructed area upwind 20 Sign Height Sign Height Above Ground, ft, H; Sign cannot be higher than top of wall or 60'. For multiple signs use worst case. USE MORE FASTENERS IF THE SIGN NEEDS IT! ONLY ATTACH TO STRUCTURAL WALL MATERIAL (UNO). Shape and strength of sign Sign Area Gross Sign Area, scift, means the overall area surrounding and Table including all sign letters and logos. may require more fasteners. Example: 'I' may need 2 fasteners, 'J" - 3, 'H"- 4, *W'- 5; and 1/8' thick plastic may need more fasteners to avoid THE ADDITIONAL SIGN LOAD AND ROTATION bending. Follow sign manufacturer's instructions, and code requirements for placement of fasteners. At least put one in each comer top and bottom. Raceway sign fasteners spaced evenly in two rows 5 - 7" apart, half on top row, and hall on bottom row. Follow fastener manufacturer's instructions and code requirements for installation. z E CALCULATION: Minimum Number of Fasteners c � Evenly Spaced Over Whole Sign aV1 ( Fasteners = Wind Force on Whole Sign Area / Fastener Allowable Tension ) m Fasteners for Whole Sign Use More if Si n Needs It Fastener Wall Structure Pull Fastener Installation 8 8 8 3/8 or 1/2 ThruBolt 8x8xl" steel Attach sign frame to existing steel tube w/ mounting500 pipe (2) fasteners with 4" min. between fasteners 8 8 8 1/4" or #14 Metal 8x8xl" steel 455 Attach sign frame to existing steel tube w/ Screw mounting pipe (2) fasteners with 4" min between fasteners 3.0" SIGN FACE / FRAME DESIGNED BY OTHERS (NOT PART OF THIS SEAL) 7" x 4 1/2" RACEWAY MOUNTED ON TOP OF SUPPORT TUBE FASTENERS FROM SIGN TO MOUNTING TUBES PER TABLE w! MIN. 4" SPACING EXISTING 8" x 8" x 1" THICK STEEL TUBE BY OTHERS ;NOT PART OF THIS SEAL) 2015 INTERNATIONAL refASCE7-10 BUILDING CODE If Risk Category Il, Normal hazard to human life; III, Substantial hazard to human I ---- iY_ - y 1I -,-r----------------, life; IV, Essential, emergency, critical 115 Wind Speed Basic Wind Speed, Ultimate, mph, from ASCE7-10, Fig26.5-1A, i Risk 11; or Fig.26.5-1B, Risk III&IV C Exposure Wind Exposure C, No unobstructed area within 120Dft; Wind Exposure D, Unobstructed area upwind 20 Sign Height Sign Height Above Ground, ft, H; Sign cannot be higher than top of wall or 60'. For multiple signs use worst case. See Sign Area Gross Sign Area, scift, means the overall area surrounding and Table including all sign letters and logos. & C wind pressure on solid sign attached flat against wall or parallel to wall, <3' iron surface and >T from edge, equals wall wind pressure from ASCE7-10, Section 30.4. assure; Pasd = Ohasd'Gcp, ASD. C&C, ASCE7-10, Eg30.4.1 Pressure; Ohasd=.00256'Kz'Kzt'Kd'VasdA 2, ASCE7-10,Eq.30.3.1 eed: Vasd = sart(VuIt12'.6). for allowable stress desion ial Pressure Coeff; GCp=-1.8, Zone 5, 1ft2 area, ASCE7.10, Fig30.4- Direction Factor, Kd =.85 for attached signs, ASCE7-10, Table26.6-1 51 psf ISign Weight; must be less than 5 pounds per sq.ft. net area. I — - so' -4" .� ...+. 31,. a..-� rti� tH11— j_ I ---- iY_ - y 1I -,-r----------------, �. i I THIS SIGN IS ADDING ADDITIONAL LOAD AND ROTATION TO THE EXISTING BUILDING STEEL. DESIGN PROFFESSIONAL LOWELL W. TAYLOR MUST VERIFY THAT THE EXISTING BUILDING STEEL CAN SUPPORT THE ADDITIONAL SIGN LOAD AND ROTATION -f 114.1" 011a C, t a 17-7 MARK DISOSWAY, PE 163 SW Midtown PI, Ste 1 " - Lake City, Florida 3202r 386-754.5419 TXPE102516Firm125 x .�! M S 1?jSC >FJAY I!j (14�`��CidA..... L� 10/19/2018 seal for structural engineering per e of work (Fasteners only) (See equation) I IS NOT: architecture, electric, or of sign and wall. 1. Select fastener from table based on wall structure. 2. Install fasteners per fastener manufacturer instructions in locations required by sign manufacturer; this may mean more fasteners are required than shown in table. 3. Make sure sign and wall meets building code, sign code, and UL. Verify stated wind (speed, risk, exp, topo), sign (size, area, location on wall, max weight), wall (materials and PASTED IMAGES, DETAILS, DRAWINGS, AND TOTES ON THIS SHEET ARE NOT ENGINEEREI OR REVIEWED. They were pasted in at customers request to help relate fastener engineering to the job. C, U Lc�-- o5 The Router Room F1:7:�iEtiL WALL SIGN Flat on wall max 12" thick. Mustang Panther Stadium 3001 Ira E Woods Ave Grapevine, TX 76051 For two signs same type at this location SITE PLAN REVIEW COMMITTEE NOVEMBER 7, 2018 STATE OF TEXAS COUNTY OF TARRANT CITY OF GRAPEVINE The Site Plan Review Committee of the City of Grapevine, Texas met in Session, on this the 7t" day of November, 2018, in the Planning and Zoning Conference Room, 200 South Main Street, Second Floor, Grapevine, Texas with the following members present -to -wit: Larry Oliver Chairman Darlene Freed Member Scott Williams Member Constituting a quorum and the following City Staff: Ron Stombaugh Development Services Assistant Director Albert Triplett Jr. Planner II Susan Batte Planning Technician CALL TO ORDER Chairman Oliver called the meeting to order at 1:32 p.m. NEW BUSINESS CONDITIONAL USE APPLICATION CU18-26 — HILTON GARDEN INN First for the Committee to consider was conditional use application CU18-26 for property located at 2200 Bass Pro Court and platted as Lot 1, Block 1, Silver Lake Crossing. The applicant was requesting a conditional use permit amend the previously approved site plan of CU16-23 and planned development overlay, PD16-08 for a planned commercial center in conjunction with a 300 room co -branded hotel, specifically to allow for slight modifications to the building footprint, and building material changes. The applicant also proposed the addition of a temporary, 158 off-site parking area to the immediate north of the subject property to provide necessary parking during the construction of the hotel addition After a brief discussion, Darlene Freed to approve conditional use application CU18-26 with the condition that the temporary parking shall be removed within one year of the completion of the Hilton Garden Inn. Scott Williams seconded the motion, which prevailed by the following vote: Ayes: Oliver, Freed and Williams Nays: None CONSIDERATION OF MINUTES 110718 1 SITE PLAN REVIEW COMMITTEE NOVEMBER 7, 2018 Next for the Committee to consider were the Site Plan Review Committee minutes of October 3, 2018 minutes. Darlene Freed moved to approve the Site Plan Review Committee minutes of October 3, 2018. Scott Williams seconded the motion, which prevailed by the following vote: Ayes: Oliver, Freed and Williams Nays: None ADJOURNMENT With no further business to discuss, Larry Oliver adjourned the meeting at 1:41 p.m. PASSED AND APPROVED BY THE SITE PLAN REVIEW COMMITTEE OF THE CITY OF GRAPEVINE, TEXAS ON THIS THE 6T" DAY OF FEBRUARY 2019. /_1 JT:7�1�/�1; W99" ATTEST: PLANNING TECHNICIAN 110718 2 SITE PLAN REVIEW COMMITTEE FEBRUARY 6, 2019 STATE OF TEXAS COUNTY OF TARRANT CITY OF GRAPEVINE The Site Plan Review Committee of the City of Grapevine, Texas met in Session, on this the 6th day of February 2019, in the Planning and Zoning Conference Room, 200 South Main Street, Second Floor, Grapevine, Texas with the following members present -to -wit: Larry Oliver Scott Williams Chairman Member Constituting a quorum with Darlene Freed absent and the following City Staff: Ron Stombaugh Development Services Assistant Director Albert Triplett Jr. Planner II Susan Batte Planning Technician Chairman Oliver called the meeting to order at 1:30 p.m. NEW BUSINESS CONDITIONAL USE APPLICATION CU19-05 — GRAPEVINE/COLLEYVILLE ISD First for the Committee to consider was conditional use application CU19-05 for property located at 3001 Ira E Woods Avenue and platted as Education Center No. 3, Block 1, Lot 1A. The applicant was requesting a conditional use permit allow an archway sign for Mustang -Panther Stadium. The applicant proposed installing a two and one-half foot, 79.15 -square foot internally illuminated archway sign attached to the brick columns above the home side arched entrance of the stadium. The overall height of the sign when placed atop the entry columns is 19 -feet. After a brief discussion, Larry Oliver to approve conditional use application CU19-05. Scott Williams seconded the motion, which prevailed by the following vote: Ayes: Oliver and Williams Nays: None CONSIDERATION OF MINUTES Next for the Committee to consider were the Site Plan Review Committee minutes of November 7, 2018 minutes. 020619 1 SITE PLAN REVIEW COMMITTEE FEBRUARY 6, 2019 Larry Oliver to approve the Site Plan Review Committee minutes of November 7, 2018. Scott Williams seconded the motion, which prevailed by the following vote: Ayes: Oliver and Williams Nays: None ADJOURNMENT With no further business to discuss, Larry Oliver adjourned the meeting at 1:33 p.m. PASSED AND APPROVED BY THE SITE PLAN REVIEW COMMITTEE OF THE CITY OF GRAPEVINE, TEXAS ON THIS THE 6T" DAY OF MARCH 2019. CHAIRMAN ,f W.W �) A� 020619 2