Loading...
HomeMy WebLinkAboutPLBG2019-0801CityofGrapevine P.O.Box95104 Grapevine,TX76099 (817)410-3165Voice (817)410-3012Fax PLUMBINGPERMIT{VALUE} IssueDate:March4,2019 PROJECTDESCRIPTION:Replaced2"double-checkbybuilding10 PROJECT# PLBG-19-0801 (817)410-3010 Inspections www.mygov.us Permits LOCATIONLEGAL 601ParkBlvd. Building#10 Grapevine,TX76051 TheBlk1Lot1 WoodlakeAptsAddition CONTRACTOR KPKPlumbingLLC. StateID#M-40738 1502NorthMasonStreet Bowie,TX76230 (940)841-1173Phone (940)841-1173Mobile OWNER FrontlineGrapevineLp 9460WilshireBlvdSuite850 BeverlyHills,CA90212 AVAILABLEINSPECTIONS BackflowDeviceInspection(required) TCEQBackflowCertificationSubmit (required) PlumbingFinal(required) INFORMATION County Tarrant SquareFootage VALUATION 1000 Zoning FEESTOTAL=$45.00 PlumbingPermitFee{VALUE}$45.00 PAYMENTSTOTAL=$45.00 KPKPlumbingLLC.(SammiePoe) Ccon03/04/2019 ($45.00) NOTICES ALLworkmustbedoneincompliancewiththe2006INTERNATIONAL PLUMBINGCODE. PLANSUBMITTAL:WHENPLANSAREREQUIREDBYCODES, ORDINANCES,ORASDETERMINEDBYTHEBUILDINGOFFICIAL,THREE (3)SETSOFPLANSSHALLBESUBMITTEDINHARDCOPYFORMAT. ENGINEERSEALEDPLANSANDCALCULATIONSSHALLBESUBMITTED ASREQUIREDBYCODES,ORDINANCESORWHEREOTHERWISE REQUIREDBYSTATELAW. READANDSIGN IHEREBYCERTIFYTHATTHEFOREGOINGISCORRECTTOTHEBEST OFMYKNOWLEDGEANDALLWORKWILLBEPERFORMEDACCORDING TOTHEDOCUMENTSAPPROVEDBYTHEBUILDINGDEPARTMENTAND INCOMPLIANCEWITHTHECITYOFGRAPEVINECODESREGULATING CONSTRUCTION.ITISUNDERSTOODTHATTHEISSUANCEOFTHIS PERMITDOESNOTGRANTORAUTHORIZEANYVIOLATIONOFANY CODEORORDINANCEOFTHECITYOFGRAPEVINE. IFURTHERCERTIFYTHATALLWORKTHATISREQUIREDTOCOMPLY WITHANYFEDERAL,STATE,AND/ORLOCALLAWREGARDINGENERGY CONSERVATIONWILLBEPERFORMEDINACCORDANCEWITHTHOSE LAWS,ANDTHATVERIFICATIONOFENERGYCODECOMPLIANCESHALL BESUBMITTEDTOTHECITYUPONREQUEST. MYGOV.USCityofGrapevine|PLUMBINGPERMIT{VALUE}|PLBG-19-0801|Printed03/06/19at9:03a.m.Page1of3 Perm,+-f CITY of GRAPEVINE BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT NAME OF PWS: GRAPEVINE ANNUAL TEST IRRIGATION PWS I.D.# 2200013 11 111 II OTHER= NAME OF BUSINESS WHERE DEVICE IS LOCATED: U.AL DA Oorffi, 170.f Y� ADDRESS OF SITE SERVICED: Ion, fj- PAIL— SIVA. PLUMBING PERMIT IF APPLICABLE: # Iff—ONI TESTER LICENSE NUMBER: 6POG1?31x7 EXPIRES: cyIaallq DATE OF LAST TEST GAUGE CALIBRATION: 10 19 k THE BACKFLOW PREVENTION ASSEMBLY DETAILED BELOW HAS BEEN TESTED AND MAINTAINED AS REQUIRED BY TCEQ REGULATIONS AND IS CERTIFIED TO BE OPERATING WITHIN ACCEPTABLE PARAMETERS. TYPE OF ASSEMBLY _ REDUCED PRESSURE PRINCIPLE —PRESSURE VACUUM BREAKER DOUBLE CHECK _ATMOSPHERE VACUUM BREAKER � ^ I , MANUFACTURER: W•ll� S SIZE: a MODEL: '35() �GI� 1 SEERInAL IDo�NUMBER: s(Q tp 0 PHYSICAL LOCATION OF METER @, f of C pti'iC04j 410 REDUCED PRESSURE PRINCIPLE ASSEMBLY PRESSURE VACUUM BREAKER DOUBLE CHECK VALVE AIR INLET CHECK VALVE ASSEMBLY 1sT CHECK 2ND CHECK RELIEF VALVE DC-Closed Tight Closed Tight Opened at Open at psid _psid Initial _RP�psid H Did not open Leaked Test psid `C Leaked Leaked Repair Materials Used Test DC-Closed Tight Opened at Opened at After Closed Tight psid Repair RP psid psid psid L The above is certified to be true. TESTERS FIRM NAME: hi1Te$"I ADDRESS: �rT'IL4 CITY/STATE/ZIP: Rftxwwi*'j:15C 1-malo DATE: 3Iq/l9 II PHONE NUMBER: 5 PRINT NAME: Kylf" M'\�+klav"C l SIGNATURE: ' ✓ L ^rT DOUBLE CHECK VALVE INSPECTION MUST BE CALLED FOR INSPECTION AT(817) 410-3010 ReoAtes sN : G4(Q!5-(> 0AFORMSVDS JPpjGATTON INFOA6ACEFLOW TEST REPORT doc Revised.1/06,2/10