Loading...
HomeMy WebLinkAboutAlpha Testing - 2/7/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:DRILLED PIERS Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-81 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:1/10/2018 Time Placed:11:20 AM 8.0 1.4 51.0 56.0 Date Received:1/12/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:141 Delivery Ticket No.:4440340 155.9 Batch Time:10:22:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:53135214 Break Type: Sample Location:PIERS PB8, PB11 PM:TIM BEGOLE SR. Date Issued:02/07/2018 Specified Strength:3500 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 133 1/17/2018 7 3588012.56 2860LABC-1231 8 N/A 41 134 2/7/2018 28 5794012.56 4610LABC-1231 8 N/A 42 135 2/7/2018 28 5097012.56 4060LABC-1231 8 N/A 41 136 2/7/2018 28 5743012.56 4570LABC-1231 8 N/A 41 Average 28-day Compressive Strength is compliant with project specifications CC: 4410 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 303810 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.