HomeMy WebLinkAboutAlpha Testing - 1/12/20181 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Respectfully Submitted, YesYesYesConcrete Placed Same Day (Yes or No)Yes Yes Page Number:1 of 1Grapevine, Texas Time Concrete Was Placed 2:20 PM 2:55 PM 3:10 PM 2:40 PM 10:25 AM 2:10 PM Time Drilling Was Completed 11:00 AM 11:30 AM 10:40 AM 11:40 AM 12Stirrup Spacing (in.)12 12 12 12 Stirrup Size (#)3 3 3 3 35.70 3 Length of Vertical Bars (ft.)39.80 37.00 40.80 33.00 Number of Vertical Bars (each)7 7 7 6 7 6 7 18 Dry 18 30 9.50 12.60 -0.28 37.28 9.50 9.70 1.47 6 23 22 28.53 Dry 18 18 31.58 Dry Tim Begole Sr. Remarks: Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Client: Condition of Bottom (Wet or Dry) General Contractor: Pier Identification Pier Diameter (in.) Required Penetration (ft.) Actual Penetration (ft.) Top of Ground Elevation (ft.) Casing Diameter (in.) Cased Depth (ft.)25 Vertical Bar Size (#)6 6 Building B Restroom F171917 Abima, Cornelius Grapevine - Colleyville ISD 30510 Ira E Woods Ave Grapevine, Texas 76051 Newstar DrillingLee Lewis Construction Building/Structure Identification Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Drilled Straight Shaft Pier Observation Report Mustang Panther Stadium Service Date: Report Date: Weather: Work Order Number: Project Number: Technician: 1/12/2018 1/18/2018 Clear Project: Drilling Contractor: PB7 18 PB16 18 PB5 18 PB15 18 346668 Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Depth From Top Of Concrete To Bottom Of Pier (ft.) Measured Depth From Ground Level To Top Of Concrete (ft.) Top of Pier Elevation (ft.) Depth of Bearing Stratum From Ground (ft.) Total Depth of Drilled Pier From Ground (ft.) approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-008(8/2/2016) PB10 18 598.50 598.78 598.50 598.78 598.50 597.03 598.50 598.78 598.50 597.03 25.30 24.00 34.00 24.40 37.0035.20 31.30 9.50 21.2020.30 30.00 9.50 9.90 9.50 10.1010.00 -0.28 -0.281.47 35.48 32.53 Dry Dry Statement: If elevations are provided, they were provided by OTHERS and assumed to be correct. 32 18