HomeMy WebLinkAboutAlpha Testing - 4/12/2018 (3)Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:GRADE BEAMS: BUILDING B Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-149 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:3/15/2018 Time Placed:12:30 PM 5.8 4.1 62.0 64.0 Date Received:3/20/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Weldemariam, Tesfai Plant Number:143 Delivery Ticket No.:4565071 150 Batch Time:11:32:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8272DP Break Type: Sample Location:BK/B12 TO BC/12 PM:TIM BEGOLE SR. Date Issued:04/12/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 244 3/22/2018 7 9803028.27 3470LABC-1231 12 N/A 61 245 4/12/2018 28 12100028.27 4280LABC-1231 12 N/A 61 246 4/12/2018 28 12219028.27 4320LABC-1231 12 N/A 63 247 4/12/2018 28 12054028.27 4260LABC-1231 12 N/A 62 248 HOLD HOLD 028.27LABC-1231 12 N/A 6 Average 28-day Compressive Strength is compliant with project specifications CC: 4290 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 311487 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:GRADE BEAMS: BUILDING B Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-150 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:3/15/2018 Time Placed:3:10 PM 6.0 6.0 71.0 68.0 Date Received:3/20/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Weldemariam, Tesfai Plant Number:141 Delivery Ticket No.:45658823 143.6 Batch Time:2:14:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8272DP Break Type: Sample Location:BB/B5 TO BB/B1 PM:TIM BEGOLE SR. Date Issued:04/12/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 249 3/22/2018 7 7747028.27 2740LABC-1231 12 N/A 63 250 4/12/2018 28 9514028.27 3370LABC-1231 12 N/A 65 251 4/12/2018 28 9244028.27 3270LABC-1231 12 N/A 65 252 4/12/2018 28 9494028.27 3360LABC-1231 12 N/A 65 253 HOLD HOLD 028.27LABC-1231 12 N/A 6 Average 28-day Compressive Strength is compliant with project specifications CC: 3330 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 311488 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.