Loading...
HomeMy WebLinkAboutAlpha Testing - 4/4/2018 (2)5058 Brush Creek Road Fort Worth, Texas 76119 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Our test results and reports are for the exclusive use of the client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. April 4, 2018 Grapevine - Colleyville ISD 30510 Ira E Woods Ave Grapevine, TX 76051 Attention: Ms. Calva Powell Re: Field Inspection of Structural Steel Mustang Panther Stadium Pkg A & Pkg B Grapevine, Texas ALPHA Report No. F171917-172 Alpha Testing arrived on site to perform a Visual Structural Steel Inspection for the above referenced project. Results of the inspection are as follows: I Beam to Embed TCA325 Bolted and Welded Connections - Concession Stand “B” Crawl Space – lines C1 to C13 & CJ to C16: A. Visually inspected the (5”x3”x1/2”) clip angles to embed welded connections per detail 1/S3.2. Angles were welded to the embeds with ¼’ fillet weld on (3) sides. Reference details 2/S3.3 to 4/S3.3. Compliant. B. The TCA325 bolts for the clip angle to beam connections were installed with hardened washers and 3/8” bar washers and were properly tensioned. Reference detail 1/3.2 and “Structural Steel Connections” general note (6). Complaint. II TCA325 Beam to Beam Bolted Connections - Concession Stand “B” Crawl Space – lines C1 to C13 & CJ to C16: A. The TCA325 bolts were installed with hardened washers and were properly tensioned. Reference “Structural Steel Connections” general note (6). Complaint. III W21x44 Beam Splice Welded Connections - Concession Stand “B” Crawl Space – lines C1 to C13 & CJ to C16: A. Visually inspected the W21x44 beam splice welded connections per details 1/E11 and 2/S3.2 with no discrepancies found at time of inspection. 3/8” shear plates were welded on both sides of the beam web at the splice with ¼” filet welds on (3) sides. Compliant. IV W21x44 to Column Plate Welded Connections - Concession Stand “B” Crawl Space – lines C1 to C13 & CJ to C16: A. Visually inspected the W21x44 beam to column plate welded connections per detail 2/S3.2 with no discrepancies found at time of inspection. The beam was welded to the column plate with ¼” fillet welds on both sides. Compliant. *Discrepancies, if any, are noted above in bold. INSPECTOR: John W. Butler CWI#18011071 5058 Brush Creek Road Fort Worth, Texas 76119 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Our test results and reports are for the exclusive use of the client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA Report No. F171917-172 We are pleased to be of service on this project and if you have any questions, please contact our office. Sincerely yours, ALPHA TESTING, INC. Tim Begole Sr. Project Manager