Loading...
HomeMy WebLinkAboutAlpha Testing - 12/1/2017Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:DRILLED PIERS Project Desc:MUSTANG PANTHER STADIUM Our Report #:F171917-43 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:11/3/2017 Time Placed:10:15 AM 8.0 2.1 53 73 Date Received:11/8/2017 Concrete Supplier:N/A Submitted By:Abima, Cornelius Plant Number:N/A Delivery Ticket No.:N/A 150.7 Batch Time:N/A Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:N/A Break Type: Sample Location:PIERS PC-14 & PC-15 PM:TIM BEGOLE SR. Date Issued:12/01/2017 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 50 11/10/20177 4712012.56 3750LABC-1231 8 N/A 45 51 12/1/2017 28 6444012.56 5130LABC-1231 8 N/A 45 52 12/1/2017 28 6615012.56 5270LABC-1231 8 N/A 42 53 12/1/2017 28 6307012.56 5020LABC-1231 8 N/A 45 54 12/29/201756 012.56LABC-1231 8 N/A 4 Average 28-day Compressive Strength is compliant with project specifications CC: 5140 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 297453 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.