Alpha Testing - 1/11/2018 (3)
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING IN FIRELANE Project Desc:MUSTANG PANTHER STADIUM Our Report #:F171917-73 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:12/14/2017 Time Placed:7:20 AM 7.5 5.8 44.0 65.0 Date Received:12/18/2017 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:131 Delivery Ticket No.:4406344 147.9 Batch Time:6:07:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:R3156066 Break Type: Sample Location:STA 1+15 PM:TIM BEGOLE SR. Date Issued:01/11/2018 Specified Strength:3600 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 119 12/15/20171 1260012.56 1000LABC-1231 8 N/A 45 120 12/21/20177 5192012.56 4130LABC-1231 8 N/A 42 121 1/11/2018 28 7055012.50 5640LABC-1231 8 N/A 3.991 122 1/11/2018 28 6162012.56 4910LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 5280 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 301872 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING IN FIRELANE Project Desc:MUSTANG PANTHER STADIUM Our Report #:F171917-74 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:12/14/2017 Time Placed:9:22 AM 7.0 7.0 50.0 65.0 Date Received:12/18/2017 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:141 Delivery Ticket No.:4406813 145.9 Batch Time:7:46:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:R31156066 Break Type: Sample Location:STA. 0+50 PM:TIM BEGOLE SR. Date Issued:01/11/2018 Specified Strength:3600 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 123 12/15/20171 1423012.56 1130LABC-1231 8 N/A 42 124 12/21/20177 4637012.56 3690LABC-1231 8 N/A 41 125 1/11/2018 28 6836012.56 5440LABC-1231 8 N/A 42 126 1/11/2018 28 6111012.50 4890LABC-1231 8 N/A 3.993 127 1/11/2018 28 6552012.56 5220LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 5180 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 301873 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.