Loading...
HomeMy WebLinkAboutAlpha Testing - 12/28/2017Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RETAINING WALL FOOTING Project Desc:MUSTANG PANTHER STADIUM Our Report #:F171917-58 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:11/29/2017 Time Placed:10:32 AM 7.5 6.0 55 70 Date Received:12/1/2017 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:141 Delivery Ticket No.:4374477 148.3 Batch Time:9:18:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-173) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206M Break Type: Sample Location:STATION3+15 PM:TIM BEGOLE SR. Date Issued:12/28/2017 Specified Strength:3600 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 79 12/6/2017 7 5479012.56 4360LABC-1231 8 N/A 42 80 12/27/201728 7186012.56 5720LABC-1231 8 N/A 43 81 12/27/201728 7319012.56 5830LABC-1231 8 N/A 41 82 12/27/201728 7089012.56 5640LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications Notes:Additional slump test performed on later truck measured to be 6.0" CC: 5730 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 300150 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.