Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Alpha Testing - 1/8/2019
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:STADIUM WALKWAY ENTRANCE Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-488956-S1 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:12/11/2018 Time Placed:7:13 AM 4.0 3.8 32.0 54.0 Date Received:12/13/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Powell, Charles Plant Number:131 Delivery Ticket No.:5117326 154 Batch Time:6:28:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:TT2418 Break Type: Sample Location:25' N AND 40' W FROM SE CORNER OF TICKET BOOTH PM:TIM BEGOLE SR. Date Issued:01/08/2019 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 751 12/18/20187 6351012.56 5060LABC-1231 8 N/A 41 752 1/8/2019 28 7888012.56 6280LABC-1231 8 N/A 41 753 1/8/2019 28 7965012.56 6340LABC-1231 8 N/A 42 754 1/8/2019 28 8224012.56 6550LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 6390 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 344025 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:STADIUM WALKWAY ENTRANCE Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-488956-S2 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:12/11/2018 Time Placed:12:50 PM 6.3 4.7 59.0 61.0 Date Received:12/13/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Powell, Charles Plant Number:131 Delivery Ticket No.:5118778 152 Batch Time:12:07:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:TT2417M Break Type: Sample Location:5' N AND 10' W FROM SE CORNER OF TICKETBOOTH PM:TIM BEGOLE SR. Date Issued:01/08/2019 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 755 12/18/20187 5695012.56 4530LABC-1231 8 N/A 42 756 1/8/2019 28 7580012.56 6040LABC-1231 8 N/A 43 757 1/8/2019 28 7197012.56 5730LABC-1231 8 N/A 45 758 1/8/2019 28 7389012.56 5880LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 5880 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 344026 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.