HomeMy WebLinkAboutAlpha Testing - 10/12/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-451142-S1 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:9/14/2018 Time Placed:5:37 AM 4.5 4.2 72.0 84.0 Date Received:9/25/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Andrade, Fernando Plant Number:141 Delivery Ticket No.:4964890 141.1 Batch Time:4:39:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:STATION 3+60 FROM RETAINING WALL PM:TIM BEGOLE SR. Date Issued:10/12/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 683 9/24/2018 10 5646012.56 4500LABC-1231 8 N/A 42 684 10/12/201828 7046012.56 5610LABC-1231 8 N/A 42 685 10/12/201828 7021012.56 5590LABC-1231 8 N/A 42 686 10/12/201828 6835012.56 5440LABC-1231 8 N/A 41 Average 28-day Compressive Strength is compliant with project specifications CC: 5550 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 335386 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-451142-S2 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:9/14/2018 Time Placed:7:15 AM 6.0 3.9 72.0 84.0 Date Received:9/25/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Andrade, Fernando Plant Number:141 Delivery Ticket No.:4965286 141.1 Batch Time:6:38:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:STATION 2+70 FROM RETAINING WALL PM:TIM BEGOLE SR. Date Issued:10/12/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 687 9/24/2018 10 5051012.56 4020LABC-1231 8 N/A 45 688 10/12/201828 6153012.56 4900LABC-1231 8 N/A 42 689 10/12/201828 5902012.56 4700LABC-1231 8 N/A 41 690 10/12/201828 6044012.56 4810LABC-1231 8 N/A 41 Average 28-day Compressive Strength is compliant with project specifications CC: 4800 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 335387 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-451142-S3 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:9/14/2018 Time Placed:11:12 AM 3.0 3.2 79.0 88.0 Date Received:9/25/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Andrade, Fernando Plant Number:145 Delivery Ticket No.:4966188 146.7 Batch Time:10:24:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:STATION 0+50 FROM RETAINING WALL PM:TIM BEGOLE SR. Date Issued:10/12/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 691 9/24/2018 10 4535012.56 3610LABC-1231 8 N/A 42 692 10/12/201828 5441012.56 4330LABC-1231 8 N/A 42 693 10/12/201828 5303012.56 4220LABC-1231 8 N/A 45 694 10/12/201828 5593012.56 4450LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4330 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 335388 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.