Loading...
HomeMy WebLinkAboutAlpha Testing - 10/11/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RETAINING WALL: WALL 4B Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-450738 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:9/13/2018 Time Placed:12:22 PM 7.0 2.5 80.0 88.0 Date Received:9/14/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:131 Delivery Ticket No.:4963574 151.6 Batch Time:11:04:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8206 M Break Type: Sample Location:STATION 0+60 TO CONTROL JOINT STATION 0+87 PM:TIM BEGOLE SR. Date Issued:10/11/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 679 9/20/2018 7 4653012.56 3700LABC-1231 8 N/A 43 680 10/11/201828 6100012.56 4860LABC-1231 8 N/A 43 681 10/11/201828 5439012.56 4330LABC-1231 8 N/A 45 682 10/11/201828 6138012.56 4890LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 4690 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 334188 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.