HomeMy WebLinkAboutAlpha Testing - 8/29/2018 (3)Size of Reinforcement X RW1.6; C8.7 (Driveway), C6.5 (Pavement Connection to New Driveway); C6.5 Concrete Retaining Wall Shedule for Wall Face Height 3ft, 6ft and ft; Keyway Joint, Pavement Connection; 1 4/10/2017; 1/5/2018•Date: Plan Sheet: Observation Information N/AItem Observed N/ACorrectNot Correct X Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Grapevine - Colleyville ISD 30510 Ira E Woods Ave Grapevine, TX 76051 Main Entrance Driveway: 100 to 250' W of Press Box Mustang Panther Stadium Pkg A & Pkg B Project Number: Retaining Wall Foundation: Wall 4B Stations 0+00 to 1+95 08/29/2018Service Date: 9/4/2018 Client: Reinforcing Steel Observation Report Report Date: Grapevine, Texas Page Number: 444944 1 of • • The representative observed the reinforcing steel related items for the following area: An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled. 1 Clear Project: Weather: F171917 Technician:Abima, Cornelius Work Order Number: •Firelane: Behind East Bleachers Retaining Wall Stations 3+50 to 5+00 X X • Detail Sheet:• The representative utilized the following provided project plans to perform the observation: Bar Length & Spacing Correct X Based on the representative's visual observation using the provided project plans, the area Proper Placement Drawings Approved The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office. X Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Reinforcement Tied Properly Correct Splicing was compliant approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016) Tim Begole Sr. Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Respectfully Submitted, Not Correct Item Observed Proper Cover Proper Support X Reinforcement Clean Form Clean X X Dowels in Place X X Remarks: Grade Reinforcement Number of Reinforcement X X X Grade Beam / Column Size X Stirrup Size Stirrup Spacing X X Cable/Tendon Count & Spacing XPT Drawings Cable/Tendon Drape X Sheathing X