HomeMy WebLinkAboutAlpha Testing - 8/17/2018 (2)1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Grapevine - Colleyville ISD 30510 Ira E Woods Ave Grapevine, TX 76051 Service Date: Report Date: Weather: 08/17/2018 8/21/2018 Partly Cloudy Concrete Placed Same Day (Yes or No) Work Order Number: Project Number: Technician: 2:20 PM 4:00 PM 4:50 PM3:40 PM 439682 4:55 PM4:40 PM 4:45 PM Yes Yes Yes F171917 Billingsley, Ernest (Alan) 1of2 Yes Yes 3:50 PM Yes Yes Yes Yes 1:40 PM 1:30 PM 2:30 PM Yes Yes Yes Yes Yes Yes 2:00 PM8:30 AM 8:53 AM 9:09 AM 1:20 PM 3:45 PM2:40 PM 2:50 PM 3:15 PM 5 19.50 19.00 77 5 5 5 7 7 5 5 7707 2:50 PM 1:40 PM Stirrup Size (#)7 7 7 Stirrup Spacing (in.)5 5 5 Time Concrete Was Placed 2:20 PM 2:10 PM 1:58 PM 1:50 PM 8:10 AMTime Drilling Was Completed 7:20 AM 7:40 AM 7:50 AM 5 5 5 5 555 5 7 7 7 5 5 5 Length of Vertical Bars (ft.)18.00 18.00 18.00 5 5 5 7 18.30 18.00 17.50 18.00 18.0021.00 18.00 18.00 18.00 18.00 7 7 5 5 18 597.13 595.13 18 596.02 594.42 7 77 7 7 77 N/A N/A N/A N/A N/A N/A 1.902.00 15.00 Wet N/A N/AN/A N/A N/A N/A Dry 15.20 15.2018.60 Dry 16.70 Dry 16.50 Wet 17.40 15.5016.10 5 N/A N/A N/A Vertical Bar Size (#)7 7 N/A N/A N/A Number of Vertical Bars (each)5 Required Penetration (ft.) 189 18 N/A N/A 190182 18 596.88 594.98 N/A 18.20 N/A N/A N/A N/A approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-008(8/2/2016) Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Remarks: Respectfully Submitted, Tim Begole Sr. Casing Diameter (in.) Cased Depth (ft.) 184 N/A Depth From Top Of Concrete To Bottom Of Pier (ft.) 191 N/A 1.601.60Measured Depth From Ground Level To Top Of Concrete (ft.) Actual Penetration (ft.) 2.80 N/A 5 5 7 777 5 Page Number: Masonry Fence Post Basees 18 597.32 601.49 18 181818 181183 603.24 General Contractor: Pier Identification Pier Diameter (in.) Top of Ground Elevation (ft.) Top of Pier Elevation (ft.) Depth of Bearing Stratum From Ground (ft.) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Project: Drilling Contractor: Client: Condition of Bottom (Wet or Dry) New Star DrillingLee Lewis Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Drilled Straight Shaft Pier Observation Report Grapevine, Texas Mustang Panther Stadium Pkg A & Pkg B Building/Structure Identification 18 18 18 18 604.33 18.30 595.92 600.29601.54 N/A 599.29 599.19602.73 199192193194195196197198 Total Depth of Drilled Pier From Ground (ft.) 599.00 597.98 18 18 598.28602.89 604.49 602.61 602.10 600.80 597.31 597.21 595.50 595.40 20.0020.00 595.18 N/A N/A 595.28 N/A N/AN/A N/A 16.60 16.40 21.00 20.80 20.75 20.00 20.40 20.00 N/A N/A N/A N/A 17.00 20.50 N/AN/AN/A 17.70 N/A N/A N/A N/A N/A N/A N/A N/A N/A 3.00 N/A N/A N/A N/A N/A N/A N/A N/A N/A 5.30 3.601.70 Dry Dry 15.45 15.11 1.40 1.20 3.60 5.30 5.30 4.89 Dry Dry 16.40 Dry Dry 15.10 N/A N/AN/A N/A N/A N/A Statement: If elevations are provided, they were provided by OTHERS and assumed to be correct. N/A N/A N/AN/A N/A N/A N/A N/A N/A Dry Dry 17.20 17.00 Wet Dry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Drilled Straight Shaft Pier Observation Report Client:Grapevine - Colleyville ISD Service Date:08/17/2018 Grapevine, TX 76051 Weather:Partly Cloudy 30510 Ira E Woods Ave Report Date:8/21/2018 2 Technician:Billingsley, Ernest (Alan) Work Order Number:439682 Project:Mustang Panther Stadium Pkg A & Pkg B Project Number:F171917 General Contractor:Lee Lewis Drilling Contractor: of 2 Building/Structure Identification Masonry Fence Post Basees New Star Drilling Grapevine, Texas Page Number: Pier Identification 116 Pier Diameter (in.)18 Top of Ground Elevation (ft.)597.39 Top of Pier Elevation (ft.)593.59 Depth of Bearing Stratum From Ground (ft.)N/A Required Penetration (ft.)N/A Actual Penetration (ft.)N/A Total Depth of Drilled Pier From Ground (ft.)19.90 Depth From Top Of Concrete To Bottom Of Pier (ft.)16.10 Condition of Bottom (Wet or Dry)Dry Measured Depth From Ground Level To Top Of Concrete (ft.)3.80 Vertical Bar Size (#)7 Casing Diameter (in.)N/A Cased Depth (ft.)N/A Length of Vertical Bars (ft.)18.00 Number of Vertical Bars (each)5 Stirrup Spacing (in.)5 Stirrup Size (#)7 Time Drilling Was Completed 4:10 PM Time Concrete Was Placed 5:00 PM Statement: If elevations are provided, they were provided by OTHERS and assumed to be correct. Concrete Placed Same Day (Yes or No)Yes Remarks: Respectfully Submitted, Tim Begole Sr. Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-008(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering