Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SIDEWALK: AREA 9, BUILDING C Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-366 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:8/3/2018 Time Placed:6:15 AM 4.5 4.0 77.0 88.0 Date Received:8/6/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Guerrero, Victor Plant Number:141 Delivery Ticket No.:4883863 148.8 Batch Time:5:10:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:50' N AND 3' W FROM SW CORNER OF BUILDING C PM:TIM BEGOLE SR. Date Issued:08/31/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 592 8/10/2018 7 4749012.56 3780LABC-1231 8 N/A 42 593 8/31/2018 28 5978012.56 4760LABC-1231 8 N/A 42 594 8/31/2018 28 6014012.56 4790LABC-1231 8 N/A 43 595 8/31/2018 28 6029012.56 4800LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 4780 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 329449 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SIDEWALK: AREA 9, BUILDING C Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-367 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:8/3/2018 Time Placed:9:40 AM 5.5 4.2 82.0 93.0 Date Received:8/6/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Guerrero, Victor Plant Number:141 Delivery Ticket No.:4884866 148.4 Batch Time:8:14:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:50' N AND 15' E FROM SE CORNER OF BUILDING C PM:TIM BEGOLE SR. Date Issued:08/31/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 596 8/10/2018 7 4992012.56 3970LABC-1231 8 N/A 45 597 8/31/2018 28 5898012.56 4700LABC-1231 8 N/A 42 598 8/31/2018 28 6009012.56 4780LABC-1231 8 N/A 43 599 8/31/2018 28 5949012.56 4740LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4740 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 329450 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.