Alpha Testing - 8/22/2018
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RETAINING WALL Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-348 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/25/2018 Time Placed:9:14 AM 5.8 3.3 86.0 86.0 Date Received:7/27/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Patterson, Jeremy Plant Number:141 Delivery Ticket No.:4862541 N/A Batch Time:8:36:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8206M Break Type: Sample Location:RW-9A PM:TIM BEGOLE SR. Date Issued:08/22/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 560 8/1/2018 7 4392012.56 3500LABC-1231 8 N/A 45 561 8/22/2018 28 5403012.56 4300LABC-1231 8 N/A 43 562 8/22/2018 28 5738012.56 4570LABC-1231 8 N/A 43 563 8/22/2018 28 5873012.56 4680LABC-1231 8 N/A 43 Average 28-day Compressive Strength is compliant with project specifications CC: 4520 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 327939 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RETAINING WALL Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-349 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/25/2018 Time Placed:10:34 AM 3.5 3.1 86.0 89.0 Date Received:7/27/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Patterson, Jeremy Plant Number:145 Delivery Ticket No.:4862896 N/A Batch Time:9:56:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8205M Break Type: Sample Location:RW-14 PM:TIM BEGOLE SR. Date Issued:08/22/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 564 8/1/2018 7 3826012.56 3050LABC-1231 8 N/A 42 565 8/22/2018 28 4839012.56 3850LABC-1231 8 N/A 42 566 8/22/2018 28 4918012.56 3920LABC-1231 8 N/A 45 567 8/22/2018 28 4972012.56 3960LABC-1231 8 N/A 43 Average 28-day Compressive Strength is compliant with project specifications CC: 3910 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 327940 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.