Loading...
HomeMy WebLinkAboutAlpha Testing - 8/23/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: STADIUM LOCKER ROOM FIRELINE AND PARKING LOT Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-351 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/26/2018 Time Placed:6:03 AM 5.3 3.3 75.0 92.0 Date Received:7/30/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Macias, Jose Plant Number:141 Delivery Ticket No.:4864589 151.5 Batch Time:5:16:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:10' N AND 50' E FROM NE CORNER OF LOCKER ROOM PM:TIM BEGOLE SR. Date Issued:08/23/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 568 8/2/2018 7 5084012.56 4050LABC-1231 8 N/A 42 569 8/23/2018 28 5682012.56 4520LABC-1231 8 N/A 45 570 8/23/2018 28 6245012.56 4970LABC-1231 8 N/A 45 571 8/23/2018 28 5913012.56 4710LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 4730 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 328147 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: STADIUM LOCKER ROOM FIRELINE AND PARKING LOT Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-352 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/26/2018 Time Placed:9:22 AM 4.0 3.8 85.0 93.0 Date Received:8/1/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Macias, Jose Plant Number:141 Delivery Ticket No.:4865631 152.6 Batch Time:8:39:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:15' N AND 8' W FROM NE CORNER OF LOCKER ROOM PM:TIM BEGOLE SR. Date Issued:08/23/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 572 8/2/2018 7 5759012.56 4590LABC-1231 8 N/A 42 573 8/23/2018 28 6409012.56 5100LABC-1231 8 N/A 42 574 8/23/2018 28 6764012.56 5390LABC-1231 8 N/A 42 575 8/23/2018 28 6813012.56 5420LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 5300 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 328148 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: STADIUM PARKING LOT E, WEST ENTRANCE Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-353 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/26/2018 Time Placed:11:49 AM 5.0 4.4 95.0 94.0 Date Received:7/30/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Macias, Jose Plant Number:141 Delivery Ticket No.:4866158 150.8 Batch Time:10:17:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F8206W Break Type: Sample Location:25' N AND 60' W FROM SW CORNER OF STADIUM ENTRANCE PM:TIM BEGOLE SR. Date Issued:08/23/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 576 8/2/2018 7 3626012.56 2890LABC-1231 8 N/A 45 577 8/23/2018 28 4595012.56 3660LABC-1231 8 N/A 43 578 8/23/2018 28 4748012.56 3780LABC-1231 8 N/A 42 579 8/23/2018 28 5004012.56 3980LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 3810 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 328149 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.