Loading...
HomeMy WebLinkAboutAlpha Testing - 8/16/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SIDEWALK: BUILDING B Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-338 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/19/2018 Time Placed:8:35 AM 6.0 1.5 90.0 91.0 Date Received:7/20/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Kabwang Jonathan Plant Number:7216 Delivery Ticket No.:91932 152.6 Batch Time:7:35:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F9508M Break Type: Sample Location:BB/B1 PM:TIM BEGOLE SR. Date Issued:08/16/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 544 7/26/2018 7 4721012.56 3760LABC-1231 8 N/A 45 545 8/16/2018 28 6491012.56 5170LABC-1231 8 N/A 42 546 8/16/2018 28 6485012.56 5160LABC-1231 8 N/A 45 547 9/13/2018 56 012.56LABC-1231 8 N/A 4 Average 28-day Compressive Strength is compliant with project specifications CC: 5160 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 327160 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:WALL 9A STATION 03+35 TO STATION 03+90 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-339 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:7/19/2018 Time Placed:1:05 PM 6.0 1.5 101.0 95.0 Date Received:7/20/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Kabwang Jonathan Plant Number:7216 Delivery Ticket No.:91936 149 Batch Time:12:00:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8206A Break Type: Sample Location:STATION 03+35 PM:TIM BEGOLE SR. Date Issued:08/16/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 548 7/26/2018 7 4755012.56 3790LABC-1231 8 N/A 45 549 8/16/2018 28 6162012.56 4910LABC-1231 8 N/A 42 550 8/16/2018 28 6807012.56 5420LABC-1231 8 N/A 42 551 9/13/2018 56 012.56LABC-1231 8 N/A 4 Average 28-day Compressive Strength is compliant with project specifications CC: 5160 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 327161 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.