Loading...
HomeMy WebLinkAboutAlpha Testing - 7/26/2018 (2)Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SIDEWALK BETWEEN LOWER CONCOURSE AND UPPER CONCOURSE BLEACHER Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-318 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:6/28/2018 Time Placed:7:25 AM 5.0 2.6 79.0 90.0 Date Received:7/2/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:131 Delivery Ticket No.:4804929 150.6 Batch Time:6:46:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:R3141230 Break Type: Sample Location:N/A PM:TIM BEGOLE SR. Date Issued:07/26/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 513 7/5/2018 7 4988012.56 3970LABC-1231 8 N/A 42 514 7/26/2018 28 6453012.56 5140LABC-1231 8 N/A 41 515 7/26/2018 28 6158012.56 4900LABC-1231 8 N/A 45 516 7/26/2018 28 6783012.56 5400LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 5150 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 324566 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:THREE LIGHT POLE BASES Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-319 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:6/28/2018 Time Placed:11:35 AM 8.0 4.8 89.0 90.0 Date Received:7/2/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:141 Delivery Ticket No.:4806311 152.8 Batch Time:6:46:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3131214 Break Type: Sample Location:LIGHT POLE BY RETAINING WALL 5 PM:TIM BEGOLE SR. Date Issued:07/26/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 517 7/5/2018 7 4322012.56 3440LABC-1231 8 N/A 42 518 7/26/2018 28 5329012.56 4240LABC-1231 8 N/A 45 519 7/26/2018 28 5625012.56 4480LABC-1231 8 N/A 41 520 7/26/2018 28 5423012.56 4320LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 4350 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 324567 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.