Loading...
HomeMy WebLinkAboutAlpha Testing - 6/18/2018105.2 19.8 125.4 126.9 20.0 97 98 96 95 96 19.8 106.4 19.3 126.6 105.5 95 126.0 103.9 20.7 104.6 19.8 General Location Area:Retaining Wall Backfill Field Test Data 1 Retaining Wall 9B Backfill at Staircase FG-1.0 1 3 Retaining Wall 9B Backfill at Staircase FG 1 5 Retaining Wall 9A Backfill, Sta. 3+25 FG-2.0 1 Retaining Wall 9A Backfill, Sta. 3+25 FG-1.5 Optimum Moisture (%) Test No.Test Location Lift/ Depth Material Information 1 1 6 6 7 Retaining Wall 9A Backfill, Sta. 3+25 FG-1.0 1 6 6 6 2 Grapevine, TX 76051 Weather:Cloudy 412482Work Order Number: 1 Technician:Gasigwa, Ignace(Baziga) 125.1 104.3 30510 Ira E Woods Ave Report Date:6/25/2018 Client:Grapevine - Colleyville ISD Service Date:06/18/2018 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report Compaction Min. (%) Max.Material Description/Classification Project Specifications Grapevine, Texas Page Number:1 of Project Number:F171917 Moisture Min. (%) Max. Laboratory Data Max Dry Weight (pcf) Proctor Report No. Project:Mustang Panther Stadium Pkg A & Pkg B Mat. No. 15.8 109.1 2 64Brown Sandy Clay 9893 Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. 4 Retaining Wall 9A Backfill, Sta. 3+25 FG-2.5 1 Retaining Wall 9B Backfill at Staircase FG-0.5 1 6 6 Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Compaction (%) 19.9 6 124.6 104.0 125.3 Serial No:32453 Manufacturer:Troxler Model:3430 Percent Moisture (%) Standard Count: 96 (M):670(D):2486 Remarks: Respectfully Submitted, Tim Begole Sr. approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written