Loading...
HomeMy WebLinkAboutAlpha Testing - 6/11/2018 (4)103.0 20.5 124.2 21.0 94 94 94 98 21.7 123.7 102.2 93 124.1 102.8 20.8 105.3 17.6 General Location Area:Retaining Wall Field Test Data 1 Retaining Wall 9B Backfill at Staircase FG-6.0 1 3 Retaining Wall 9B Backfill at Staircase FG-5.0 2 5 Retaining Wall 9B Backfill at Staircase FG-4.0 2 Retaining Wall 9B Backfill at Staircase FG-3.5 Optimum Moisture (%) Test No.Test Location Lift/ Depth Material Information 1 2 6 6 6 6 2 Grapevine, TX 76051 Weather:Clear 409188Work Order Number: 1 109.1 Technician:Gasigwa, Ignace(Baziga) 122.9 105.7 30510 Ira E Woods Ave Report Date:6/14/2018 Client:Grapevine - Colleyville ISD Service Date:06/11/2018 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report Compaction Min. (%) Max.Material Description/Classification Project Specifications Grapevine, Texas Page Number:1 of Project Number:F171917 Moisture Min. (%) Max. Laboratory Data Max Dry Weight (pcf) Proctor Report No. Project:Mustang Panther Stadium Pkg A & Pkg B 98 Mat. No. Brown Sandy Clay 16.7 107.1 6 934215.8 -1 33Brown and Tan Sandy Clay 95 2 Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. 4 Retaining Wall 9B Backfill at Staircase FG-4.5 2 Retaining Wall 9B Backfill at Staircase FG-5.5 1 6 6 Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Compaction (%) 16.3 6 124.0 101.9 123.8 Serial No:32453 Manufacturer:Troxler Model:3430 Percent Moisture (%) Standard Count: 99 (M):667(D):2481 Remarks: Respectfully Submitted, Tim Begole Sr. approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written