HomeMy WebLinkAboutAlpha Testing - 12/6/2017Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING: PARKING LOT Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-28-S1 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:10/11/2017 Time Placed:11:20 AM 2.75 4.9 64 80 Date Received:10/13/2017 Concrete Supplier:MARTIN MARIETTA Submitted By:Wilson, Jason Plant Number:1313 Delivery Ticket No.:4271956 148.4 Batch Time:10:19:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:R3156066 Break Type: Sample Location:30'N & 35'W OF NW BUILDING CORNER PM:TIM BEGOLE JR. Date Issued:12/06/2017 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 20 10/12/20171 3068012.56 2440LABC-1231 8 N/A 41 21 10/18/20177 5728012.56 4560LABC-1231 8 N/A 42 22 11/8/2017 28 6745012.56 5370LABC-1231 8 N/A 41 23 11/8/2017 28 6905012.56 5500LABC-1231 8 N/A 42 24 12/6/2017 56 7684012.56 6120LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 5440 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 294199 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.