Loading...
HomeMy WebLinkAboutAlpha Testing - 6/6/2018 (3)Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RET WALL 5 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-250 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:5/9/2018 Time Placed:11:50 AM 5.5 4.1 80.0 85.0 Date Received:5/15/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:131 Delivery Ticket No.:4690121 151.7 Batch Time:10:25:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8274M Break Type: Sample Location:STATION 00+10 PM:TIM BEGOLE SR. Date Issued:06/06/2018 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 401 5/16/2018 7 4562012.56 3630LABC-1231 8 N/A 45 402 6/6/2018 28 5948012.56 4740LABC-1231 8 N/A 42 403 6/6/2018 28 5505012.56 4380LABC-1231 8 N/A 43 404 6/6/2018 28 5919012.56 4710LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4610 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 317912 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.