Loading...
HomeMy WebLinkAboutAlpha Testing - 5/10/2018 (2)Size of Reinforcement Correct Splicing Based on the representative's visual observation using the provided project plans, the area was compliant XNumber of Reinforcement X Proper Placement Reinforcement Tied Properly X X X X Dowels in Place X 05/10/2018 1 Partly Cloudy 5/15/2018 F171917 Correct X X Not Correct N/A Proper Cover Technician:Gasigwa, Ignace(Baziga) N/A Correct Project: Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled. Grapevine - Colleyville ISD 30510 Ira E Woods Ave Reinforcing Steel Observation Report Work Order Number: Project Number: Service Date:Client: Grapevine, Texas Page Number: 395191 1 of Grapevine, TX 76051 Report Date: Weather: Remarks: Drawings Approved Grade Reinforcement Observation Information • Detail Sheet:• Plan Sheet: X Mustang Panther Stadium Pkg A & Pkg B Reinforcement Clean Form Clean X The representative observed the reinforcing steel related items for the following area: Geotechnical Engineering | Construction Materials Testing | Environmental Engineering Retaining Wall 6 The representative utilized the following provided project plans to perform the observation: Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written • Bar Length & Spacing Grade Beam / Column Size approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016) Tim Begole Sr. Stirrup Spacing Stirrup Size Respectfully Submitted, The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office. X X X •Date: X X Proper Support RW1.11 RW 1.2; RW 1.4; RW 1.6 5/17/2017 Not Correct Item ObservedItem Observed X PT Drawings Cable/Tendon Count & Spacing X SheathingCable/Tendon Drape Weather:Partly Cloudy Work Order Number:395191 Client:Grapevine - Colleyville ISD Service Date:05/10/2018 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 Reinforcing Steel Observation Report Page Number: An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled. 1 30510 Ira E Woods Ave Report Date:5/15/2018 Grapevine, Texas Technician:Gasigwa, Ignace(Baziga) of 1 Project:Mustang Panther Stadium Pkg A & Pkg B Project Number:F171917 Grapevine, TX 76051 The representative observed the reinforcing steel related items for the following area: •Footings at Retaining Wall 9 A; 9B and Steps •Date:1/17/2018 •Plan Sheet: The representative utilized the following provided project plans to perform the observation: Item Observed Correct Not Correct N/AItem Observed CorrectNot Correct N/A RW 1.13 •Detail Sheet:RW 1.3; RW 1.5; RW 1.6 Grade Reinforcement X Drawings Approved X Proper Cover X Bar Length & Spacing X Dowels in Place X Proper Support X Number of Reinforcement X Reinforcement Clean X Form Clean X Size of Reinforcement X Stirrup Spacing X The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office. Stirrup Size XProper Placement X Reinforcement Tied Properly X Correct Splicing X X Sheathing X Based on the representative's visual observation using the provided project plans, the area was compliant Cable/Tendon Drape Grade Beam / Column Size X XPT Drawings X Cable/Tendon Count & Spacing Remarks: Respectfully Submitted, Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016) Tim Begole Sr. Geotechnical Engineering | Construction Materials Testing | Environmental Engineering