An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled.
Grapevine - Colleyville ISD
30510 Ira E Woods Ave
Reinforcing Steel
Observation Report
Work Order Number:
Project Number:
Service Date:Client:
Grapevine, Texas Page Number:
395191
1 of
Grapevine, TX 76051
Report Date:
Weather:
Remarks:
Drawings Approved
Grade Reinforcement
Observation Information
•
Detail Sheet:•
Plan Sheet:
X
Mustang Panther Stadium Pkg A & Pkg B
Reinforcement Clean
Form Clean
X
The representative observed the reinforcing steel related items for the following area:
Geotechnical Engineering | Construction Materials Testing | Environmental Engineering
Retaining Wall 6
The representative utilized the following provided project plans to perform the observation:
Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written
•
Bar Length & Spacing
Grade Beam / Column Size
approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-019(8/2/2016)
Tim Begole Sr.
Stirrup Spacing
Stirrup Size
Respectfully Submitted,
The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office.
X
X
X
•Date:
X
X
Proper Support
RW1.11
RW 1.2; RW 1.4; RW 1.6
5/17/2017
Not Correct Item ObservedItem Observed
X
PT Drawings
Cable/Tendon Count &
Spacing X
SheathingCable/Tendon Drape
Weather:Partly Cloudy
Work Order Number:395191
Client:Grapevine - Colleyville ISD Service Date:05/10/2018
Alpha Testing, Inc.
5058 Brush Creek Rd
Fort Worth, TX 76119
www.alphatesting.com
TBPE Firm No. 813
Reinforcing Steel
Observation Report
Page Number:
An Alpha Testing engineering representative traveled to the above referenced project to perform a reinforcing steel observation as scheduled.
1
30510 Ira E Woods Ave Report Date:5/15/2018
Grapevine, Texas
Technician:Gasigwa, Ignace(Baziga)
of 1
Project:Mustang Panther Stadium Pkg A & Pkg B Project Number:F171917
Grapevine, TX 76051
The representative observed the reinforcing steel related items for the following area:
•Footings at Retaining Wall 9 A; 9B and Steps
•Date:1/17/2018
•Plan Sheet:
The representative utilized the following provided project plans to perform the observation:
Item Observed Correct Not Correct N/AItem Observed CorrectNot Correct N/A
RW 1.13
•Detail Sheet:RW 1.3; RW 1.5; RW 1.6
Grade Reinforcement X
Drawings Approved X Proper Cover X
Bar Length & Spacing X Dowels in Place X
Proper Support X
Number of Reinforcement X
Reinforcement Clean X
Form Clean X
Size of Reinforcement X
Stirrup Spacing X
The contractor was notified of the observation result and the engineering representative returned to the Fort Worth Office.
Stirrup Size XProper Placement X
Reinforcement Tied Properly X
Correct Splicing X
X Sheathing X
Based on the representative's visual observation using the provided project plans, the area was compliant
Cable/Tendon Drape
Grade Beam / Column Size X
XPT Drawings X Cable/Tendon Count &
Spacing
Remarks: