HomeMy WebLinkAboutAlpha Testing - 12/1/2017 (2)Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PARKING LOT Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-22-S1 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:10/6/2017 Time Placed:9:20 AM 3.5 4.4 77 87 Date Received:10/10/2017 Concrete Supplier:MARTIN MARIETTA Submitted By:Wilson, Jason Plant Number:141 Delivery Ticket No.:4261847 149.2 Batch Time:8:32:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:R3156066 Break Type: Sample Location:120'N & 84'W OF NW CORNER OF BUILDING PM:TIM BEGOLE JR. Date Issued:12/01/2017 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 15 10/7/2017 1 012.56LABC-1231 8 N/A 4 16 10/13/20177 6193012.56 4930LABC-1231 8 N/A 41 17 11/3/2017 28 7703012.56 6130LABC-1231 8 N/A 42 18 11/3/2017 28 7806012.56 6210LABC-1231 8 N/A 41 19 HOLD HOLD 012.56LABC-1231 8 N/A 4 Average 28-day Compressive Strength is compliant with project specifications CC: 6170 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 293940 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.