HomeMy WebLinkAboutAlpha Testing - 4/24/2018 (3)5 Retaining Wall Backfill at BK/B9 93
8 Retaining Wall Backfill at BK/B8 124.4 105.1
FG-3.0
4 Retaining Wall Backfill at BK/B7 124.8
9717.9
9419.7
96
93
102.8
18.4 96
123.5
101.6
1 Retaining Wall Backfill at BK/B8 FG-3.5
Retaining Wall Backfill at BK/B9
7
976
1
104.8
106.0 18.0
123.7
1
19.1
FG-2.5 1 6
6
125.1
Retaining Wall Backfill at BK/B8 123.16
Retaining Wall Backfill at BK/B8
6 123.9 105.2
21.8
101.5 21.7
Gasigwa, Ignace(Baziga)
388382Work Order Number:
Moisture
Min. (%) Max.
Compaction
Min. (%) Max.
04/24/2018
1
Material Description/Classification
4/30/2018
Project:Mustang Panther Stadium Pkg A & Pkg B Project Number:F171917
Grapevine, TX 76051 Weather:Partly Cloudy
Alpha Testing, Inc.
5058 Brush Creek Rd
Fort Worth, TX 76119
www.alphatesting.com
TBPE Firm No. 813
In-Place Nuclear Density
Test Report
Material Information Laboratory Data
30510 Ira E Woods Ave Report Date:
Client:Grapevine - Colleyville ISD Service Date:
Technician:
Project Specifications
Grapevine, Texas Page Number:1 of
Mat.
No.
Optimum
Moisture
(%)
Max Dry
Weight
(pcf)
Proctor
Report No.
1 15.8 109.1 2 64Brown Sandy Clay 9893
Field Test Data
Test
No.Test Location Lift/
Depth
Mat.
No.
Probe
Depth
(in.)
Wet
Density
(pcf)
General Location
Area:Wall backfill North of Building B
Dry
Density
(pcf)
Percent
Moisture
(%)
Percent
Compaction
(%)
Gauge Information Non-compliant results are indicated by an asterisk(*) if
applicable.
1 6
1
FG 1 6
FG-0.5
3 Retaining Wall Backfill at BK/B7
2
6
96
FG-1.5 1 6
FG-2.0 1
FG-1.0
125.2 106.2
17.8
Standard Count:(D):2504 (M):678
Remarks:
Model:3430Serial No:32453 Manufacturer:Troxler
Tim Begole Sr.
Respectfully Submitted,
Geotechnical Engineering | Construction Materials Testing | Environmental Engineering
This report is in general compliance with one or more of the following technical standards: D6938-15
Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our writtenapproval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016)