Loading...
HomeMy WebLinkAboutAlpha Testing - 10/11/2017Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PAVING PATCH ON MUSTANG DRIVE Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-2-S1 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:9/13/2017 Time Placed:1:30 PM 4.0 4.25 86 95 Date Received:9/15/2017 Concrete Supplier:MARTIN MARIETTA Submitted By:Guerrero, Victor Plant Number:131 Delivery Ticket No.:4216561 148.8 Batch Time:2:32:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:R3156066 Break Type: Sample Location:MANHOLE STATION 0+00 PM:TIM BEGOLE JR. Date Issued:10/11/2017 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 1 9/14/2017 1 3640012.56 2900LABC-1231 8 N/A 41 2 9/20/2017 7 5425012.56 4320LABC-1231 8 N/A 45 3 10/11/201728 6963012.56 5540LABC-1231 8 N/A 41 4 10/11/201728 6711012.56 5340LABC-1231 8 N/A 43 5 10/11/201728 6807012.56 5420LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 5430 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 290929 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.