HomeMy WebLinkAboutAlpha Testing - 4/4/2018 (3)98 103.1 18.7 122.6 123.3 18.2 97 96 96 96 123.4 105.1 17.4 97 17.6 103.2 19.5 122.8 103.9 97 122.4 102.9 19.1 12 Electrical Line at Westside of Building A FG-3.0 125.7106" Water Line Back Flow Prevention at Station 1+82 104.1 17.8 8 Grade Beam at A .3/11.4 FG-1.0 2 6 18.6 General Location Area: Field Test Data 1 Grade Beam at E.1/11.11 FG-1.0 2 3 Grade Beam at E.2/11.13 FG-1.0 2 5 Grade Beam at F.5/11.13 FG-1.0 2 FG-3.0 3 Grade Beam at E.6/11.13 FG-1.0 Optimum Moisture (%) Test No.Test Location Lift/ Depth 9 6" Water Line Back Flow Prevention at Station 1+83 Material Information 4 1 2 6 12 7 Grade Beam at A .2/11.4 FG-1.0 2 12 12 12 12 2 Grapevine, TX 76051 Weather:Clear 379361Work Order Number: 2 107.1 Technician:Weldemariam, Tesfai 122.4 103.6 30510 Ira E Woods Ave Report Date:4/10/2018 Client:Grapevine - Colleyville ISD Service Date:04/04/2018 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report Compaction Min. (%) Max.Material Description/Classification Project Specifications Grapevine, Texas Page Number:1of Project Number:F171917 Moisture Min. (%) Max. Laboratory Data Max Dry Weight (pcf) Proctor Report No. Project:Mustang Panther Stadium Pkg A & Pkg B 3 15.8 109.1 2 6 Mat. No. Brown and Sandy Clay Brown Clay 14.9 112.6 93 3 953 98 2 16.7 -1 31Reddish Brown Clayey Sand 95 -1 Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. 103.3 18.4 96 Electrical Line at Westside of Building A 4 Grade Beam at E.2/11.13 FG-1.0 2 106.6 Grade Beam at E.1/11.12 FG-1.0 2 6 6 98 98 2 12 Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) 6 107.1 17.9 Percent Compaction (%) 18.1 6 122.3 104.0 122.6 3 12 122.2 126.1 17.9 106.938 Serial No:1246 Manufacturer:Humboldt Model:H5001 EZ Percent Moisture (%) FG-2.0 2 103.2 18.26122.0 126.3 104.1 17.4 13 122.3 Standard Count: FG-1.0 2 122.0 102.912 97 98 14 Electrical Line at Westside of Building A FG-1.0 2 96 96 15 Electrical Line at Westside of Building A FG-2.0 11 6" Water Line Back Flow Prevention at Station 1+85 FG-0.67 97 18.0 (M):487(D):1933 Remarks: Respectfully Submitted, Tim Begole Sr. approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Respectfully Submitted, Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Tim Begole Sr. Standard Count:(D):1933 Remarks: 487 Non-compliant results are indicated by an asterisk(*) if applicable. Manufacturer:Humboldt Model:H5001 EZ Gauge Information Serial No:1246 (M): 9714.2 17 Retaining Walls 8 at Station 1+ 66 FG-2.0"1 110.0 6 125.2 127.4 109.619 18 Retaining Walls 8 at Station 1+ 72 FG-2.0"1 10 Retaining Walls 8 at Station 1+ 72 FG-2.0"1 98 976125.1 109.0 14.8 15.8 16 Retaining Walls 8 at Station 1+ 66 FG-3.0"1 10 126.4 108.9 16.1 97 Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) Moisture Min. (%) Max. Compaction Min. (%) Max. Material Information 95 Mat. No. Area: General Location 3 4 Brown Clay 15.8 109.1 98 2 3 Brown and Sandy Clay 16.7 107.1 -1 3 95 2 6 93 4/10/2018 Proctor Report No.Material Description/Classification Optimum Moisture (%) 1 1 of 2 Max Dry Weight (pcf) 112.6 -1 3 Grapevine, Texas Laboratory Data Page Number:2 Reddish Brown Clayey Sand 14.9 Project Specifications Clear Project Number:F171917 Work Order Number:379361 Technician:Weldemariam, Tesfai 30510 Ira E Woods Ave Project:Mustang Panther Stadium Pkg A & Pkg B Grapevine, TX 76051 Weather: Report Date: Client:Grapevine - Colleyville ISD Service Date:04/04/2018 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report