Loading...
HomeMy WebLinkAboutAlpha Testing - 3/23/2018Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written Tim Begole Sr. approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Respectfully Submitted, 679 Remarks: Standard Count:(D):2494 (M):Serial No:32453 Manufacturer:Troxler Model:3430 6 6 14 Sanitary Sewer Line 3 Station 0+50 FG-1.0 2 15 Sanitary Sewer Line 3 Station 0+50 FG-0.5 2 Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. 13 123.5 105.0 17.6 98 97 123.7 123.3 103.7 94 98 123.6 123.0 Percent Compaction (%) General Location Area:Utilities Field Test Data Test No.Test Location Lift/ Depth Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Mat. No. Probe Depth (in.) 15.8 110.5 22Reddish Sandy Clay Proctor Report No. 98936 Optimum Moisture (%) Max Dry Weight (pcf) Mat. No. Moisture Min. (%) Max. 2 16.7 -1 3 953Brown and Tan Sandy Clay 16.9 1of Project:Mustang Panther Stadium Pkg A & Pkg B Project Number:F171917 Technician:Gasigwa, Ignace(Baziga) 2 Material Information Laboratory Data Project Specifications Grapevine, Texas Page Number: Compaction Min. (%) Max.Material Description/Classification 1 18.9 Grapevine, TX 76051 996 105.3 17.6 104.6 18.2 107.1 3/29/2018 Client:Grapevine - Colleyville ISD Service Date:03/23/2018 Sanitary Sewer Line 3 Station 0+50 FG-1.5 2 105.8 Weather:Clear Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report Work Order Number:375206 30510 Ira E Woods Ave Report Date: 103.4 104.9 FG-3.5 2 6 7 Sanitary Sewer Line 3 Station 0+50 FG-4.5 2 5 Sanitary Sewer Line 3 Station 1+00 FG-0.5 2 6 Sanitary Sewer Line 3 Station 1+00 123.8 6 6 4 Sanitary Sewer Line 3 Station 1+00 FG-1.0 2 6 6 122.8 121.0 125.8 FG 2 FG-2.0 1 6 6 125.7 127.7 FG-1.5 2 2 6 9 Sanitary Sewer Line 3 Station 0+50 124.8 103.6 105.4 107.8 6 20.51Sanitary Sewer Line 3 Station 1+00 FG-2.5 1 2 Sanitary Sewer Line 3 Station 1+00 3 Sanitary Sewer Line 3 Station 1+00 12 Sanitary Sewer Line 3 Station 0+50 FG-2.0 2 6 11 Sanitary Sewer Line 3 Station 0+50 10 Sanitary Sewer Line 3 Station 0+50 FG-3.0 2 102.7 17.8 123.6 6 6 122.6 FG-2.5 2 8 Sanitary Sewer Line 3 Station 0+50 FG-4.0 18.1 97 19.0 18.5 98 98 98 19.2 19.3 96 98 97 125.1 105.5 103.7 105.2 18.6 99 17.1 9819.6 97 103.8 03/23/2018 Alpha Testing, Inc. 5058 Brush Creek Rd Fort Worth, TX 76119 www.alphatesting.com TBPE Firm No. 813 In-Place Nuclear Density Test Report Cloudy 30510 Ira E Woods Ave Report Date:3/29/2018 Client:Grapevine - Colleyville ISD Service Date: Work Order Number:375206 Project:Mustang Panther Stadium Pkg A & Pkg B Grapevine, TX 76051 Weather: Project Number:F171917 Moisture Min. (%) Max. Compaction Min. (%) Max. 1 Mat. No. Proctor Report No.Material Description/Classification Technician:Gasigwa, Ignace(Baziga) -1 3 of 2 95 Material Information Laboratory Data Project Specifications Grapevine, Texas Page Number:2 Max Dry Weight (pcf) 3 Brown and Tan Sandy Clay 16.7 107.1 Optimum Moisture (%) General Location Area:Utilities Field Test Data Test No.Test Location Lift/ Depth Mat. No. Probe Depth (in.) Wet Density (pcf) Dry Density (pcf) Percent Moisture (%) Percent Compaction (%) 16 Sanitary Sewer Line 3 Station 0+50 FG 1 6 122.9 104.3 17.8 97 Manufacturer:Troxler Model:3430 Standard Count:(D):2494 (M):679 Gauge Information Non-compliant results are indicated by an asterisk(*) if applicable. Serial No:32453 Respectfully Submitted, Remarks: Tim Begole Sr. approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Technician time is from portal to portal. MF-010(8/2/2016) Geotechnical Engineering | Construction Materials Testing | Environmental Engineering This report is in general compliance with one or more of the following technical standards: D6938-15 Our test results and reports are for the exclusive use of the Client (and designated recipients) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written