Alpha Testing - 4/9/2018 (2)
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RETAINING WALL: NO 7 FOOTING Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-143 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:3/12/2018 Time Placed:10:54 AM 6.8 3.1 45.0 82.0 Date Received:3/15/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:141 Delivery Ticket No.:4553327 152.4 Batch Time:9:35:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8206M Break Type: Sample Location:RETAINING WALL: NO 7 FOOTING PM:TIM BEGOLE SR. Date Issued:04/09/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 235 3/19/2018 7 7034012.56 5600LABC-1231 8 N/A 45 236 4/9/2018 28 8407012.56 6690LABC-1231 8 N/A 45 237 4/9/2018 28 8236012.56 6560LABC-1231 8 N/A 41 238 4/9/2018 28 8132012.56 6470LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 6570 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 310716 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.