Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Alpha Testing - 4/23/2018
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:GRADE BEAMS Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-166 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:3/26/2018 Time Placed:1:55 PM 4.5 3.1 80.0 91.0 Date Received:4/2/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Abima, Cornelius Plant Number:141 Delivery Ticket No.:4592694 147.6 Batch Time:12:55:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8272M Break Type: Sample Location:E.1/11.5 PM:TIM BEGOLE SR. Date Issued:04/23/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 289 4/2/2018 7 4400012.56 3500LABC-1231 8 N/A 45 290 4/23/2018 28 5489012.56 4370LABC-1231 8 N/A 42 291 4/23/2018 28 6153012.56 4900LABC-1231 8 N/A 42 292 4/23/2018 28 5768012.56 4590LABC-1231 8 N/A 41 Average 28-day Compressive Strength is compliant with project specifications CC: 4620 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 312713 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.