HomeMy WebLinkAboutAlpha Testing - 5/10/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:MIDDLE WALL: G.2/1-11, PIER CAPS: F/9-11 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-190 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:4/12/2018 Time Placed:2:15 PM 8.0 3.8 80.0 80.0 Date Received:4/16/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:141 Delivery Ticket No.:4628959 149.6 Batch Time:12:59:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3141033 Break Type: Sample Location:G.2/6 PM:TIM BEGOLE SR. Date Issued:05/10/2018 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 309 4/19/2018 7 7657012.56 6100LABC-1231 8 N/A 43 310 5/10/2018 28 8903012.56 7090LABC-1231 8 N/A 45 311 5/10/2018 28 9070012.56 7220LABC-1231 8 N/A 41 312 5/10/2018 28 9094012.56 7240LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 7180 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 314838 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.