Alpha Testing - 5/15/2018
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:1/2 WALL AT WEST ENTRY Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-200 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:4/17/2018 Time Placed:2:30 PM 8.0 4.4 81.0 79.0 Date Received:4/19/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:131 Delivery Ticket No.:N/A 149.8 Batch Time:1:42:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3141033 Break Type: Sample Location:E.2/11.12 PM:TIM BEGOLE SR. Date Issued:05/15/2018 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 329 4/24/2018 7 5120012.56 4080LABC-1231 8 N/A 45 330 5/15/2018 28 6645012.56 5290LABC-1231 8 N/A 41 331 5/15/2018 28 6479012.56 5160LABC-1231 8 N/A 45 332 5/15/2018 28 5875012.56 4680LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 5040 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 315228 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:GRADE BEAMS: G.2/0.2-1 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-201 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:4/17/2018 Time Placed:5:05 PM 6.0 4.5 82.0 79.0 Date Received:4/19/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:131 Delivery Ticket No.:4639343 151.2 Batch Time:4:15:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8272M Break Type: Sample Location:G.2/0.8 PM:TIM BEGOLE SR. Date Issued:05/15/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 333 4/24/2018 7 4607012.56 3670LABC-1231 8 N/A 42 334 5/15/2018 28 5835012.56 4650LABC-1231 8 N/A 45 335 5/15/2018 28 5710012.56 4550LABC-1231 8 N/A 42 336 5/15/2018 28 5677012.56 4520LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4570 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 315229 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.