Loading...
HomeMy WebLinkAboutAlpha Testing - 5/25/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:PRESS BOX WALL LEVEL 2 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-225 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:4/27/2018 Time Placed:3:35 PM 7.75 3.5 77 82 Date Received:5/1/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:141 Delivery Ticket No.:4667229 152.8 Batch Time:2:53:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3141033 Break Type: Sample Location:C/11 PM:TIM BEGOLE SR. Date Issued:05/25/2018 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 365 5/4/2018 7 7032012.56 5600LABC-1231 8 N/A 41 366 5/25/2018 28 8580012.56 6830LABC-1231 8 N/A 45 367 5/25/2018 28 8471012.56 6740LABC-1231 8 N/A 41 368 5/25/2018 28 8327012.56 6630LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 6730 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 316661 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:BLEACHERS BEAM: G.2/5.5 TO G.2/3.0 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-226 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:4/27/2018 Time Placed:1:15 PM 6.25 5.0 73 78 Date Received:5/1/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:141 Delivery Ticket No.:4666715 145.9 Batch Time:12:25:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3141033 Break Type: Sample Location:G.2/5.0 PM:TIM BEGOLE SR. Date Issued:05/25/2018 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 369 5/4/2018 7 4491012.56 3580LABC-1231 8 N/A 42 370 5/25/2018 28 5460012.56 4350LABC-1231 8 N/A 45 371 5/25/2018 28 5254012.56 4180LABC-1231 8 N/A 43 372 5/25/2018 28 5302012.56 4220LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4250 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 316662 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.