Loading...
HomeMy WebLinkAboutAlpha Testing - 6/6/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:BLEACHERS GRADE BEAMS AT G.2/0.12-3.0 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-249 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:5/9/2018 Time Placed:11:15 AM 6.0 5.2 78.0 83.0 Date Received:5/15/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:131 Delivery Ticket No.:4690034 146.1 Batch Time:10:13:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8272 Break Type: Sample Location:G.2/1.0 PM:TIM BEGOLE SR. Date Issued:06/06/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 397 5/16/2018 7 3908012.56 3110LABC-1231 8 N/A 45 398 6/6/2018 28 4708012.56 3750LABC-1231 8 N/A 45 399 6/6/2018 28 4960012.56 3950LABC-1231 8 N/A 45 400 6/6/2018 28 4481012.56 3570LABC-1231 8 N/A 45 Average 28-day Compressive Strength is compliant with project specifications CC: 3760 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 317911 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.