Alpha Testing - 6/26/2018
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:WESTSIDE CAST IN PLACE WALL: GROUND LEVEL AT E.2/6-11 Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-283 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:5/29/2018 Time Placed:1:35 PM 9.0 3.2 91.0 98.0 Date Received:5/31/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Gasigwa, Ignace(Baziga) Plant Number:131 Delivery Ticket No.:4735714 150.1 Batch Time:12:53:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:F9622 Break Type: Sample Location:E.2/7 PM:TIM BEGOLE SR. Date Issued:06/26/2018 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 453 6/5/2018 7 4682012.56 3730LABC-1231 8 N/A 42 454 6/26/2018 28 5998012.56 4780LABC-1231 8 N/A 42 455 6/26/2018 28 5767012.56 4590LABC-1231 8 N/A 41 456 6/26/2018 28 5883012.56 4680LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4680 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 320535 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.