Loading...
HomeMy WebLinkAboutAlpha Testing - 7/13/20185058 Brush Creek Road Fort Worth, Texas 76119 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Our test results and reports are for the exclusive use of the client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. July 13, 2018 Grapevine - Colleyville ISD 30510 Ira E Woods Ave Grapevine, TX 76051 Attention: Ms. Calva Powell Re: Field Inspection of Structural Steel Mustang Panther Stadium Pkg A & Pkg B Grapevine, Texas ALPHA Report No. F171917-334 Alpha Testing arrived on site to perform a Visual Structural Steel Inspection for the above referenced project. Results of the inspection are as follows: I Moment Welded Connections - PRESS BOX – Upper Concourse: A. The moment weld connections near lines B/10 and B/4 for the W14x22 beams were visually inspected per sheet S6.2 and detail 1/S7.2. Inspected connections were completed per detail and visually acceptable. This clears item 2(A) from report dated 7/5/18. Compliant. NOTE: TCA325 bolts have been properly tensioned at moment connections as required. II Column Anchor Bolt Connections - Bleachers – North Side Upper Concourse – lines E.2 to G.2 & 11.12 to 11: A. Connections were re-inspected per detail 9/S3.1. Column anchor bolt connections have been properly tensioned. This clears item 3(A) from report dated 7/5/18. Compliant. III (8”x4”x7/16”) angle to pre-cast anchor bolt and welded connections and (5”x5”x5/16) angle to pre- cast and beam anchors bolt and welded connections - Bleachers – North Side Upper Concourse – lines E.2 to G.2 & 11.12 to 11: A. Connections were re-inspected with no discrepancies found at time of inspection. Reference details 1/S3.5, 8/S7.8 and 10/S7.8. This clears item 5(A) from report dated 7/5/18. Compliant. IV Brace Frame Welded Connections - Bleachers – North Side Upper Concourse – lines E.2 to G.2 & 11.12 to 11: A. Connections were re-inspected per sheet S6.7 and details 2/S8.2 and 3/S8.2. Missing 5/16” fillet welds have been added. Reference BF7 and BF8 on sheet S8.2 and details 5,9,10 and 1 on sheet S8.2. This clears item 6(A) from report dated 7/5/18 Compliant. V HSS Girt to Column and Panel Welded Connections and Anchor Bolt Connections – Bleachers – North Side Upper Concourse – lines E.2 to G.2 & 11.12 to 11: A. Connections were inspected per sheet S6.7 and detail 7/S7.10 with no discrepancies found at tome of inspection. Compliant. *Discrepancies, if any, are noted above in bold. INSPECTOR: Chris Lalic CWI#16010691 5058 Brush Creek Road Fort Worth, Texas 76119 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Our test results and reports are for the exclusive use of the client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA Report No. F171917-334 We are pleased to be of service on this project and if you have any questions, please contact our office. Sincerely yours, ALPHA TESTING, INC. Tim Begole Sr. Project Manager