Loading...
HomeMy WebLinkAboutAlpha Testing - 9/4/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SLAB-ON-METAL DECK Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-371 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:8/6/2018 Time Placed:6:30 AM 6.5 2.8 79.0 87.0 Date Received:N/A Concrete Supplier:MARTIN MARIETTA Submitted By:Jensen, Eric Plant Number:131 Delivery Ticket No.:4888364 147.2 Batch Time:5:41:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3136224 Break Type: Sample Location:125' S AND 15' E FROM NW CORNER OF BUILDING PM:TIM BEGOLE SR. Date Issued:09/04/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 600 8/13/2018 7 5066012.56 4030LABC-1231 8 N/A 42 601 9/3/2018 28 6698012.56 5330LABC-1231 8 N/A 42 602 9/3/2018 28 6442012.56 5130LABC-1231 8 N/A 42 603 9/3/2018 28 6266012.56 4990LABC-1231 8 N/A 41 Average 28-day Compressive Strength is compliant with project specifications CC: 5150 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 329698 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SLAB-ON-METAL DECK Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-372 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:8/6/2018 Time Placed:11:30 AM 6.3 3.5 83.0 91.0 Date Received:8/8/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Jensen, Eric Plant Number:131 Delivery Ticket No.:4889507 149.2 Batch Time:10:42:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3136224 Break Type: Sample Location:85' N AND 10' E FROM SW CORNER OF BUILDING PM:TIM BEGOLE SR. Date Issued:09/04/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 604 8/13/2018 7 4691012.56 3730LABC-1231 8 N/A 41 605 9/3/2018 28 6438012.56 5130LABC-1231 8 N/A 41 606 9/3/2018 28 6754012.56 5380LABC-1231 8 N/A 42 607 9/3/2018 28 6451012.56 5140LABC-1231 8 N/A 41 Average 28-day Compressive Strength is compliant with project specifications CC: 5220 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 329699 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.