Loading...
HomeMy WebLinkAboutAlpha Testing - 9/22/2018Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SLAB-ON-DECK STADIUM MAIN ENTRANCE OF BLDG Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-402 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:8/25/2018 Time Placed:7:04 AM 6 1.2 81 88 Date Received:8/27/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Macias Jose Plant Number:141 Delivery Ticket No.:4932153 154.6 Batch Time:6:22:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3140224 Break Type: Sample Location:5' N AND 3' E FROM SWC OF STADIUM BLDG PM:TIM BEGOLE SR. Date Issued:09/22/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 638 9/1/2018 7 4387012.56 3490LABC-1231 8 N/A 42 639 9/22/2018 28 6006012.56 4780LABC-1231 8 N/A 45 640 9/22/2018 28 6096012.56 4850LABC-1231 8 N/A 41 641 9/22/2018 28 5836012.56 4650LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 4760 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 332196 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.