August 28, 2018
Grapevine - Colleyville ISD
30510 Ira E Woods Ave
Grapevine, TX 76051
Attention: Ms. Calva Powell
Re: Field Inspection of Structural Steel
Mustang Panther Stadium
Pkg A & Pkg B
Grapevine, Texas
ALPHA Report No. F171917-406
Alpha Testing arrived on site to perform a Visual Structural Steel Inspection for the above referenced
project. Results of the inspection are as follows:
I Type 1.5B Roof Deck – Press Box – lines G to B & 11.1 to 2:
A. A preliminary inspection was conducted on the Type 1.5B decking for the Press Box
high roof. The decking was fastened to the supports with 5/8” puddle welds on a 36/7
pattern. Side laps were fastened between spans with #10 TEK screws at 6” o/c.
Reference sheet E6.6X1, decking sheet D4 and deck fastening schedule DK2.
Compliant.
Note:To allow for ultrasonic inspection of the full penetration moment weld connections,
the decking has not been installed along the perimeter on lines G and B.
*Discrepancies, if any, are noted above in bold.
INSPECTOR:
Chris Lalic
CWI#16010691