Alpha Testing - 11/8/2018
Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:RETAINING WALL NO 3B Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-464264-S1 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:10/11/2018 Time Placed:10:50 AM 5.5 4.0 62.0 79.0 Date Received:10/15/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Guerrero, Victor Plant Number:141 Delivery Ticket No.:5015867 151.2 Batch Time:10:10:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:8206M Break Type: Sample Location:STATION 0+00 TO STATION 0+50 PM:TIM BEGOLE SR. Date Issued:11/08/2018 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 707 10/18/20187 5873012.56 4680LABC-1231 8 N/A 45 708 11/8/2018 28 7467012.56 5950LABC-1231 8 N/A 42 709 11/8/2018 28 7821012.56 6230LABC-1231 8 N/A 41 710 11/8/2018 28 7758012.56 6180LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 6120 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 337588 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Concrete Compression Test Report 5058 Brush Creek Rd. Fort Worth, TX 76119 (817)496-5600 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:STAIRS: LANDING Project Desc:MUSTANG PANTHER STADIUM PKG A & PKG B Our Report #:F171917-464264-S2 GRAPEVINE - COLLEYVILLE ISD 30510 IRA E WOODS AVE GRAPEVINE, TX 76051 CALVA POWELLATTN: Fax Number: Date Placed:10/11/2018 Time Placed:11:15 AM 6.5 6.5 62.0 76.0 Date Received:10/15/2018 Concrete Supplier:MARTIN MARIETTA Submitted By:Guerrero, Victor Plant Number:141 Delivery Ticket No.:5015864 144 Batch Time:10:01:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:S3136224 Break Type: Sample Location:NORTH AND SOUTHERN MID LANDING PM:TIM BEGOLE SR. Date Issued:11/08/2018 Specified Strength:3500 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 711 10/18/20187 5863012.56 4670LABC-1231 8 N/A 42 712 11/8/2018 28 7857012.56 6260LABC-1231 8 N/A 42 713 11/8/2018 28 7691012.56 6120LABC-1231 8 N/A 41 714 11/8/2018 28 7881012.56 6270LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC: 6220 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 337589 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.