Loading...
HomeMy WebLinkAboutECS 4/11/2019[Changeel 050 Sanell na, Suite Ec4t 4050 Worth, X Drive, Suite 500 Fort Worth, TX 76137 (682)350-2250 [Phone] (817) 847-8616 [Fax] TO: Westwood Real Estate Group 1000 Texan Trail Ste. 200 Grapvine, TX 76051 ATTN: Mr. A.L. Burtin JOB NO.: 1045 L0CATI0N:801 E. Northwest Hwy, Grapevine, TX Tarrant County We are enclosing: CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL DATE: 04/11/2019 RE: Grapevine Station North -Phase 1 PERMIT #: X Attached X For Your Use X Materials Engineering Division Concrete Reports: X As Requested CC: Westwood Group Development No. 11 - Randy Sawey Les Daigh Excavating and Demolition - Les Daigh City of Grapevine - Donald Dixson ��Pte OF tic `9s 1,S/. ..' it VINCENT JOSEPH ELDROE ............................ 105447 Ju6�9e�ILU 19 - By: Vince Elizarde Principal Engineer Disclaimer City of Grapevine - Scott Cannon Westwood Group Development No. 11 - Taylor Hazlewood Acadia Capital Group - Brad Catlett Eli Wood Construction Materials Dept. Manager 1. This report (and any attachments) shall not be reproduced except in full without prior written approval of ECS. 2. The information in this report relates only to the sample test specimens obtained on the report date. 3. The primary purpose of this report is to present the laboratory test results for the indicated sample test specimens. For a full compliance evaluation of construction eventsthat the specimens represent, this test report must be used in conjunction with the related field report. 4. Non -conforming test results will be recorded for future resolution. 5. Test results that do not meet the required strength levels at the specified ages are marked "LOW TEST RESULTS ". Transmittal Page 1/2 Khanna this name/ C 4050Sandshell Drive, Suite 500 Fort Worth.orth, TX 76137 (682)350-2250 [Phone] (817)847-8616 [Ful Project: Grapevine Station North -Phase 1 Location: 801 E. Northwest Hwy, Grapevine, TX Concrete Cylinders Strength Report Project : 1045 Set Designation: A Cast Date: 03/14/2019 Acceptance Age: 28 Days Design Strength: 4000 psi Report No.: 3 Owner: Client: Westwood Group Development No. 11 - Clint Arch.: Gen. Contr.: Struc. Eng.: Whitworth Engineering -Russell Whitworth Conc. Contr.: Placement Information Placement Location: Lot 5, Junction Box Top at Storm Drain Line 1, STA 0+00 Approx. Location Set Represents: Lot 5, Junction Box Top at Storm Drain Line 1, STA 0+00 Supplier Information (if ReadvMix) Concrete Supplier: Redi-Mix Concrete Truck No: 1588 Ticket No: 1168 Mix Designation: 101-11504 Mix Strength: 4000 psi Batch Time: 11:40 AM Added Water: - Field Test Data Tested by: Abdul K. Alokozay Air Temperature: 580 F Fresh Unit Weight: - Time Sampled: 01:00 PM Concrete Temperature: 700 F Slump/Slump Flow: 3.00 in. Air Content: 4.0 % (P) Sample # Test Date Test Age Curing Type (F/L) Average 9 Computed P Diameter (in.) v9. CrossSectional Area (in. -sq) Breaking Load (lbs) Rounded Compr. Str. (psi) Brk Type Cap Type Date to Lab 63-1045-3-1 03/21/2019 7 Lab 4.00 12.56 65280 5190 2 U 63-1045-3-2 04/11/2019 28 Lab 4.00 12.56 75072 5970 3 U 63-1045-3-3 04/11/2019 28 Lab 4.01 12.59 76365 6060 3 U 63-1045-3A 04/11/2019 28 Lab 4.00 12.56 73440 5840 3 U 63-1045-3-5 05/09/2019 1 56 Lab ,,a ,,, —.,a„U...,,,, I,orvr ,, 4 cncdpr uidl Jdilipeb niey Idve ween raven rrom me oeginnmg or me ioaa aver a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617, and cylinders denoted with Cap Type N (none) meet the planeness requirements of ASTM C39 and are tested without caps. Break Types are classified as: Type 1,2,3,4 ,5 or 6 iaw C39. Initial Curing Conditions Curing Box Curing Tank Insulated Cooled Ice Heated Other Remarks: Final Review By: Schematic of Break Type Fracture pattern per Fig 2 of C39 ®®0®®S❑❑ri Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Transmittal Page 2/2 EWood Print Date: 04/11/2019 CCBRv251