HomeMy WebLinkAboutSFRA2018-2445 International Energy Conservation Code (2015) '`�'k� F&X u Ro h Inspection ENERGY SPECIALISTS g p Form �•>„-,.�' Account: John St John site Contact: John St John Address: 405 Washington Street community/Development: North Side Addition Granevine. TX 76051 Model/Plan: 405 Washington Street Program(s): Residential IECC 2015 Good.Area(SF)/Volume(CF): 588.0 / 4704.00 Certification#: HERS: 4388262 , IECC: 8418876 Inspector/Rater: Kelvin Betters Email: Phone: 6825219895 Date: 05/03/2019 2015 IECC Compliance Path ® Sections R401-R404-Prescriptive ®Section R405-Performance ® Section R406-ERI Rough Visual Inspection Type ® ROUGH VISUAL INSPECTION l3 ROUGH VISUAL RE-INSPECTION Inspector Comments Notes: ....OK TO CORRECT AND PROCEED WITH SHEETROCK AND TO THE FINAL INSPECTION"" Please post the insulation certificate in the attic by the final inspection. The foam insulation is installed correctly without any voids, breaks, or discrepancies. The hvac unit in the attic is electric. The duct leakage test is exempt as all of the duct runs are within conditioned space and the home is code only. Air Barrier and Insulation Inspection Items Must Correct I Verified N/A 1.1 A continuous air barrier shall be installed in the building envelope. 1.2 The exterior thermal envelope contains a continuous air barrier. 1.3 Breaks or joint in the air barrier shall be sealed. 1.4 Air-permeable insulation shall not be used as a sealing material. 2.cellln Attic 2.1 Air barrier in any dropped ceilin /soff it shall be aligned with the insulation and any gaps in the air barrier sealed. _ 2.2 Access openings,drop down stair or knee wall doors to unconditioned spaces shall be sealed. 2.3 The insulation in any dropped ceiling/soffit shall be aligned with the air barrier, 3.Walls 3.1 The junction of the foundation and sill plate shall be sealed. 3.2 The junction of the top plate and the top of exterior walls shall be sealed. r- 3.3 Knee walls shall be sealed. i- 3.4 Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material r havin a thermal resistance of R-3 per inch minimum. 3.5 Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous r alignment with the air barrier. 4.Windows and Doors 4.1 The space between window/doorjambs and framing and skylights and framing shall be sealed. S.Rim Joists 5.1 Rim joists shall include the air barrier. 5.2 Rim joists shall be insulated. 6.Floors(lnciudin above-garage and cantilevered floors) 6.1 The air barrier shall be installed at any exposed edge of insulation. �. 6.2 Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking,or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing,or r (- continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Fox Energy Specialists Page 1 of 2 Toll-Free:866.448.09611 Email: ©2015 The Nelrod Company,Fort Worth,TX 76109.Fox Energy Specialists is a registered service mark of The Nelrod Company. 7.Crawl Space Walls 7.1 Exposed earth in unvented crawls aces shall be covered with a Class I vapor retarder:,ah overla pping joints tae . 7.2 Where provided instead of floor insulation,insulation shall be permanently attached to the crawlspace walls. (— r 8.Shafts,Penetrations 8.1 Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. r 9.Narrow Cavities 9.1.Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by Insulation that on installation readily r- — conforms to the available cavity space. 10.Garage Separation 10.1 Air sealing shall be provided between the garage and conditioned spaces - IA f 11.Recessed fighting 11.1 Recessed light fixtures installed in the building thermal envelope shall be sealed to the drywall. f— ■ 11.2 Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. 12.Plumbing and Wiring — -- 12.1 Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on r r installation readily conforms to available space shall extend behind piping and wiring, 13.Shower/Tub on Exterior Wail(s) 13.1 The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers&tubs. 13.2 Exterior walls adjacent to showers and tubs shall be insulated. "-- 14.ElectricaVPhone Box on Exterior Wall(s) Must Correct Verified N/A 14.1 The air barrier shall be installed behind electrical or communication boxes yr air-sealed'boxes shall be instalie6. 15.HVAC Register Boots 15.1 HVAC register boots that penetrate building thermal envelope shall be sealed to the subfloor or drywall. - 16.Fireplace 16.1 When required to be sealed,concealed fire sprinklers shall only be sealed in a manner that is recommended by _ the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cove: 1 r plates and walls or ceilings. Visual Inspection Items Thermal Envelope Walls Exterior Wall Construction Type: , Hardi Plank Wall Framing Type: Platform Exterior Wall Color: Medium Wood Vinyl Brick Stucco Stone Wall Type Insulation Type: Insulation Grade: R-value: I Stud Width(in ox.): Stud De th in : Sheathin T e: Sheathin R-Value: Siding Veneer Batt Blown Foam 01 - II III Batt Blown Foam 1 11 III Batt Blown Foam II -III Batt Blown Foam 71 II - III Batt Blown Foam 1 II " III Batt Blown Foam I If - III Batt Blown Foam 1 II III Batt Blown Foam ' I " II III Is insulation certification posted for blown or foamed walls? r" Yes r No F- N/A Attic Roof Color: Dark Attic Joist Spacing(in): 24 Radiant Barrier Installed? Yes !No Slope Ceiling Insulation Type: Thickness(in): 0 Insulation Grade: X 1 II III R-value 0 Batt Blown Foam Mechanical Decking Insulation Type: Thickness(in): 0 Insulation Grade: ■ 1 II III R-value: 0 Batt Blown Foam Attic Wall Sheathing Installed? r Yes r- No Sheathing Type? -Not Applicable- Sheathing R-value: Is the attic space foam encapsulated? i Yes F- No Attic Slope Insulation Type: ■Foam Other Thickness(in): 5.7 insulation Grade: A I F-II r III R-value: Are there any attic or crawlspace access points If yes,please list their locations: that must be installed/left open for proper ■ Yes F- No Pull down in hall for access to the hvac unit. insulation verification at final inspection? Are there any areas in the home that have bait r- yes a No If yes,please list their locations: insulation ceiling assemblies? Rough Visual Inspection Result(s): CORRECT/PROCEED Fox Energy Specialists Page 2 of 2 Toll-Free:866.448.0961 1 Email: C2015 The Nelrod Company,Fort Worth,TX 76109.Fox Energy Specialists is a registered Service mark of The Nelrod Company. INSULATION CARD - DO NOT REMOVE 13 jjjff We curie chemistry This form must be filled out and posted to comply we,bWl6ng wde and FTC-requirements. MaetslRCSectionN1101A requirements- Please postnea eiecti cal panel. PLEASE ATTACH PRODUCT TECHNICAL DATA SHEET BARE POSTING The following spray polyurethane foam Insulation systems}has been=nstailed.Consul':Wemational Buildm Code;Section 26M Foam pja, timAeion,lnternatmat Residential Code(IRCj R3 i4 Foam acs,or hrw-rWa- nal ErergyCOnSeria Code OEM)Sedlon 162 for spedfic requirements. SASP Corporation Product(s) Ins to": Enertite Series Nominal 0.5 pc€Density(Opv.-call Spey Polyurethane Foam; 17Spraytfte 1.78 Series 2.0 pcf Dens =;Ciosed-cell Spray Polasrethane Foam] Sprayiite l68 Senes 2.0 pd Denstty Spray Po yuretra ce Foam) This spray polyurethane foam insulation system has teen';nsta=.led iri accordance w`vh man-f5a:.turer's Processing deg es to provae a t e nil rsss arse d(see R-betaseY:ar re eSe). Area}nsutated R vatue ?hicMess' Attic Area R- irhes Sloped Callings R- a inches Wails{'Where: > l R- 1 3, lnch�es Walls Where:. -R- Inches Floors(aver an unheated eravAspace) R– � ) (� inches 'Cravo spae�perimeter �. '..: v incites Basement k&7ft% R– inches Other(Uytrere J ,R 9 inches '"h�om 3#tic�messesare rep;e . ^�.ive ar348id,5Pmy-epoieo Paam faterat. i keftis coder'squ 9d fue proY9c.*ian praUUt2(&7'YLQWedjTW.st#atrr..,Mr-ma;9>te3a oxim approved pry 3rd party xtGC-ESR): 164re.ft Thennal Barrier P TO Be Covered with 1,7 GypS:.iti OR Umited Access(No Stonagey Ignition Gamer: ---------4 —_.- - p—.__—_._—__—__--____—__- Jobsits Location; $ 3i Date Installed. Building Contxacto': lnsulaSionCerlb-aefor' Installed ay: CatW n—No Hot Wark-Polyurethane foam is combus Ubfe and should be treaff;4 s such. No wWding orImnkag W#08s foam has been accidental vnibon nyOPen ffawe. RASF Corpa126 INSULATION CARD DO.NOT REMOVE - c.=Ant hue ZI Z-7 tX Trri5d Tom:siw.�s�aa ..