HomeMy WebLinkAboutCA2019-84A Future With A Past
30 July 2019
Abacus Foundation Repair
1516 Osprey Drive, Suite #205
Desoto, Texas 75115
972 406-9000
RE: HISTORIC PRESERVATION COMMISSION
CERTIFICATE OF APPROPRIATENESS #CA19-84
D. E. BOX ADDITION HISTORIC DISTRICT
318 RUTH STREET
GRAPEVINE, TEXAS 76051
This letter confirms on July 30, 2019 the Historic Preservation Commission staff approved
with conditions #CA19-84 for the property addressed 318 Ruth Street, legally described
as Block 6, Lot 3, D. E. Box Addition, City of Grapevine Texas. The following was approved
on this Certificate of Appropriateness.-
1 . Repair existing foundation of house as noted;
as per the attached plans and specifications with the condition a permit be obtained
from the Building Department.
An approved Certificate of Appropriateness is not an approved building permit; a
building permit(is)/ is not required. Contact the City of Grapevine's Building
Department at 817.410.3165 for fees and information regarding permits.
Thank you,
David Klempin
Historic Preservation Officer
cc. Property Owner
CA File
THE CITY OF GRAPEVINE
HISTORIC PRESERVATION - 636 South Main Street • Grapevine, Texas 76051
Phone 817/410-3556 - Fax 817/410-3038
CERTIFICATE OF APPRnPRlATr-MC;1 ON
U~
9K1)[-1 [�����,-� �f /,-^'` / cf -(>U
�
Property Owner Name, Address & Phone Number
[�Pr®rapier�tAdd�ress Jn�c
ant Name/Occupancy/Use
RequestlDescription of Work to Be Done
2s/Sketches Attached
LMaterial Sample(s) Attached (Dlease list)
Applicant Name, Address & Phone Number
000
Mobile
Le al
Block Lot
10
Subdivision ay-)
I Photographs Attached
/h*npby certify that this information is correct to the best of my knowledioe and that the said work will be done in conformance
BuildingCodes. APPROVAL OF A CERTIFICATE OF APPROPRIATENESS DOES NOT CONSTITUTE APPROVAL OF
Z9Office Use
IN
Approved- pproved with Conditions:
Staff
HPC
0 Denied
with all submissions herein set forth, and in compliance with the City of Grapevine's Historic Overlay District Ordinances and
"-30' —a-0
THIS IS NOT A BUILDING PERMIT. V F
A SEPARATE BUILDING PERMIT MUST BE FILED AND APPROVED BY
THE BUILDING DEPARTMENT BEFORE STARTING WOWC.
HISTORIC _. OFF|CE817-41O355O
O3GSOUTH MAIN STREET, GRAPEVINE, TEXAS -
C'-Iq_0
Account #: 00252220
Georeference: 3150-6-3
Property Location: 318 RUTH ST
jurisdictions:
011 CITY OF GRAPEVINE
220 TARRANT COUNTY
906 GRAPEVINE-COLLEYVILLE ISD
224 TARRANT COUNTY HOSPITAL
225 TARRANT COUNTY COLLEGE
TARRANT APPRAISAL, DISTRICT
08/01/2019
Owner Information
HALE JAMES R JR
HALE KIM
318 RUTH ST
GRAPEVINE, TX 76051-3607
5-Year Value History
This information is intended for reference only and is subject to change. It may not accurately reflect the
complete status of the account as actuallv carried in TAD's database.
Year
Improvement Market
Land Market
Total Market
Total Appraised t
2019
$154,790
$180,000
$334,790
$162,121
2018
$116,168
$180,000
$296,168
$147,382
2017
$117,914
$180,000
$297,914
$133,984
2016
$200,394
$57,500
$257,894
$121,804
2015
$60,731
$50,000
$110,731
$110,731
A zero value indicates that the property record has not yet been completed for the indicated tax year
t Appraised value may be less than market value due to state -mandated limitations on value increases
Property Data
Legal Description: BOX, D E ADDITION Block 6 Lot 3
Deed Date: 01-30-2014
Deed Page: 0000000
Deed Volume: 0000000
Instrument: D214020462
Year Built: 1954
Agent: None
Notice Sent: 04-01-2019
Protest Deadline: 05-15-2019
State Code: A Residential SingleFamily
Approximate Size ttt: 1,580
Land Acres ♦: 0,2874
Land Sqft ♦: 12,523
ttt Rounded
♦ This represents one of a hierarchy of possible values ranked in the following order: Recorded, Computed,
System, Calculated
Exemptions
- HOMESTEAD GENERAL 11.13(b)
CA 19-9q
CROSSTOWN
ktcJ5 bole-
r
Adam A. Green, P.E. (FL & TX), MBA
Tampa: (813) 702 -3398 i Kailas/Ft. Worth (469) 751-7694
vAvw.Cz•osstotviiEligineerinacone
t3
Plan -A}
- - , .. r,,: 4
O - C.V+ Afff"I`A'kw c19 33 lsitted fi<.s
Lirc ew
urvIc
c. t F e I
Re,-Sh;M ¢ T4Fer rr rior
Usivil 5itfk 51giM5,
# rz is- c€rcxr;
;:EK t'IFiCATE OF APPROPRIATENESS
CITY OF GRAPEVINE
RELEA D o
PURSUUDF
- Q
DATE gY
ENT OF
DEVELOPMENT SERVICES
CONTACT BUILDING INSPECTIONS
FOR PERMIT INFORMATION
'LEASE NOTE: 318 Ruth St., Grapevine, TX. 76051
HIS DRAWING IS PROVIDED FOR PRELIMINARY PERMITTING AND CONSTRUCTION PURPOSES ONLY AND IS A LIMITED PLAN OF REPAIR,
ADDITIONAL WORK MAYBE NEEDED ONCE THE FOUNDATION WORK HAS BEGUN BASED ON THE PERFORMANCE OF THIS LIMITED PLAN OF
ZEPAIR. CROSSTOWN ENGINEERING HAS PROVIDED REVIEW OF THIS LIMITED PLAN OF REPAIR AND IT IS OUR OPINION THAT IT IS
ZEASONABLE AND SAFE FOR THE STRUCTURE.
GREEN
INTERIOR PIERS ARE SHOWN ON THIS DRAWING THE CONTRACTOR WILL PLACE THEM BASED ON THE LOCATIONS OF GRADE BEAMS.
......_......_..........,... 1
07.03. � g/� 116597 q•.
'LUMBING LINES AND POST TENSION CA$LES, THEREFORE, THE LOCATIONS SHOWN ON THIS MAP ARE APPROXIMATE. THE CONTRACTOR
�I1P E�.. G
P4o;, 'C
h\\�s10NAt
HALL PROVIDE THE MEANS -AND -METHODS OF THIS INSTALLATION. ADDITIONAL REPAIRS MAY BE REQUIRED UPON REVIEW OF THE
E?t
TRUCTURE BY CROSSTOWN ENGINEERING.
Crosstown Engineering
HIS IS A PROPOSED SCOPE OF WORK AND HAS NOT BEEN COMPLETED THEREFORE WE DO NOT CERTIFY ANY EXISTING OR PROPOSED
Texas Engineering Firm
OUNDATION REPAIR WORK ON THIS MAP AT THIS TIME.
(F-15944)
THE READER WOULD LIKE TO BE CERTAIN THAT ANY PROPOSED OR EXISTING REPAIRS HAVE BEEN COMPLETED THEY MUST REQUEST AN
3960 Park Ln
NGWEERING CERTIFICATE FOR THE SUBJECT FOUNDATION WORK FROM THE FOUNDATION REPAIR COMPANY.
Dallas, TX 75220
0AIq-,?q
PRESSED PILING SPECIFICATIONS
SIDE VIEW
EXISTING
STRUCTURE
FOUNDATION
STEEL SF
CONCRETE
CYLINDER;
✓/-wy
CONCRET
CAP
318 Ruth St., Grapevine, TX. 76051
FRONT VIEW
CROSSTOWN ENGINEERING
ROSSTOWNTBPE FIRM F-15944 - WWW.CROSSTOWNENGINEERING.COM
(469) 751-7694 - DALLAS METROPLEX
CA iq -'gq
CROSSTOWN
Date: July 3, 2019
Adant A. Green, P.E. (FL & TX), MBA
Tampa: (813) 702 -3398 1 Dallas/Ft. worth (469) 751-7694
www,CrossrownF eineerinr co
Attention: Abacus Foundation Repair (via email) & Property Owner
Subject: Pre -Foundation Limited Repair Consultation Report
Pier & Beam Foundation
318 Ruth St., Grapevine, TX. 76051
Crosstown Engineering (CE) was retained to conduct a review of the limited foundation repair plan prepared by
Abacus Foundation Repair (the contractor) to determine, in our opinion, if the recommended remediation plan is a
reasonable limited plan of repair based on the provided relative elevation map and the judgment of the contractor.
The contractor provided a limited repair plan that included repair locations and pre -lift elevations for the structure for
our review. No other information was provided regarding prior engineering reports, recommendations for limited
foundation repairs or construction documents. If existing piers are shown in the limited repair plan, their locations
were provided by the client and are approximated. We do not certify their performance or existence. If the reader
would like to determine if they are present, they must contact the owner or contractor to obtain an engineering certif-
icate for them.
According to the contractor, physical damage is present which indicates a need for remedial measures. Abacus
Foundation Repair has recommended performing the following:
• Installing 53 total pilings.
• Cutting 33 existing pilings.
• Demolishing and replacing approx. 213 LF of beam using 3(2x6) pressure treated wood.
• Excavating approx. 133 LF of soil under grade beam to lower.
• Reconstructing grade beam.
• Resetting/ re -shimming the interior with steel shims.
All limited repairs are to be made in the approximate locations of the structure as indicated on the limited repair plan
and may be altered based on field conditions of the foundation.
Expectations and Additional Recommendations
This report provides our reasonable professional opinion of the condition of the foundation on the date of the inspec-
tion by the contractor and is based on the data provided to us and does not take into consideration any changes in the
condition of the foundation or soils after that date. The contents of this report supersede any verbal comments made
regarding the structure before, during or after the inspection. Although document review is an integral part of the
limited foundation repair process, we recommend obtaining a visual inspection by a licensed engineer. CE can com-
plete this visual inspection for an additional fee. If Crosstown is not contracted to perform a visual inspection it is
unknown to us as to whether or not additional repairs may be needed.
This limited repair plan is intended to provide a reasonable repair to improve the performance of the foundation and
is not intended to level the foundation. The contractor shall determine the amount of elevation correction needed
based on the reaction of the structure during the lift in order to minimize damages and additional stress.
Page 1 of 6- Date: 7/3/2019
CA Iq-3q
CRd55 TOWN
Adam A. Green, P.E. (1~L &. TX), NIBA
Tampa: (813) 702 -3398 j Dallas/Ft Wo.•th (469) 751-7694
zwvvw.Crosstc)-YnPnbineerinQ com
Because the structure has endured pre -repair foundation differential movement, residual differential elevation and
perceptible floor slope or other noticeable issues may remain following the limited foundation repairs. The soils
beneath and surrounding the structure are known to shrink and swell as the seasonal soil moisture content fluctuates.
Moving forward, we anticipate that some cracks in the interior and exterior walls will surface due to seasonal move-
ment within the soils, even after limited foundation repair. Periodic repair of this type of cracking may be needed.
A foundation and yard watering and foundation maintenance program will help control seasonal movement. It is
important that the soils be stabilized and maintained with grass or ground cover around the perimeter of the structure.
In addition, tree and shrub removal or root barrier installations are advisable if trees or bushes are observed to be
close to the foundation. Tree roots can cause "heave" or settlement of the foundation where roots grow and absorb
moisture over time when planted close to the foundation (tree roots extend approximately as far or further than tree
limbs).
Maintaining the soils around the structure to slope away from the foundation to prevent excessive ponding near the
foundation in areas that are not already sloping away will help prevent future foundation movement. We recommend
that a full gutter system with gutter extensions be maintained to discharge a minimum of 4 feet from the foundation
(not in landscaped flower beds or any other location that will trap water near the foundation). Ponding near the
foundation can cause "heaving" (upward movement of the foundation), settlement of the foundation due to overly
saturated clays soil or erosion of soil embedment around the foundation.
If standing water is observed at any time in the pier and beam area by the owner, we recommend immediately pump-
ing the water out to prevent water damage to wood elements and to prevent humid conditions in the crawlspace.
Humidity in the crawlspace can cause wood rot. If standing water is observed near the foundation after a rainstorm,
we recommend consulting a drainage expert or engineer to evaluate the terrain and develop a drainage management
strategy to address the issue.
We recommend pre -lift and post -lift plumbing tests be performed on the sewer and potable plumbing lines. All leaks
shall be repaired immediately.
Page 2 of 6- Date: 7/3/2019
CA i9-�q
Adam A. Green; P.E. (FL & TX), MBA
Tampa: (813) 702 -3398 I Dallas/Ft. Worth (469) 751-7694
www.Crosstosti•nEn i.lerin,-cone
Disclaimer:
We do not warrant the future performance of the subject foundation and the reader is urged to review the Disclosure
& Disclaimer for other limitations and standard recommendations. The limit of liability is limited to the fee paid for
this opinion. No further agreement shall be made, altered, or varied except by written instrument.
This report was completed to document the repairs to be implemented by the contractor. Neither Crosstown Engi-
neering nor Adam Green, P.E., are responsible for liability to the owner or others for acts or omissions of the con-
tractor to carry out the repairs in accordance with their agreement or for the construction means, methods, techniques,
sequences, procedures or the safety precautions incident thereto. The contractor is solely responsible for the warranty
of the work they performed in accordance with their agreement.
Please see the attached disclaimer/disclosure, pier specifications and elevation map for more information.
Sincerely, -� o f �F %��
Crosstown Land Development Services t
Texas Engineering Firm FADAM A. GREEN,'
( F-15944 ) i.....,...._................................
Adam Green, P.E., MBA �� o . 116597
Professional Engineer (TX #116597) 7/3/19 410951F' /CE11S;; ,
Page 3 of 6- Date: 7/3/2019
e410 -?q
4-'#00
Adarn A. Green, P.E. (FL & `FX), MBA
RTOWN Tampa: (813) 702 -3398 ( Dallas Tt, Worth (469) 751-7694
-. lhi'4tiw.Ci'osstowr' EtigineerinL, com
DISCLOSURE & DISCLAIMER
It is known to knowledgeable professional engineers that the soils in this area are subject to movement due to expansion, con-
traction or densification of the soils etc. This soil movement could possibly cause the foundation to move after the remediation
plan within the attached report has been implemented and may impact the stability of the foundation and cause damage.
NO WARRANTY IS EXPRESSED OR IMPLIED BY THIS ENGINEER AS TO THE PERFORMANCE OF THIS FOUNDA-
TION OR THE REPAIRS THERETO. Diligent foundation maintenance to maintain consistent soil conditions along the perim-
eter should reduce further problems after the recommendations within this report have been implemented. However, seasonal
moisture variations, water leaks, erosion and other factors may affect the stability of the foundation and put it in danger of further
damage.
REPORT LIMITATIONS
This report is written for informational purposes only and is not intended to be a detailed technical evaluation of the property or
an inventory of defects. The opinions expressed in this report are based on a visual evaluation of current conditions observed at
the time of the inspection. THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, CONCERNING THIS ENGINEERING
REPORT.
The information in this report supersedes any verbal comments, expressed or implied, made by Crosstown Land Development
Services or its principals, agents or employees. The client agrees that neither CLDS nor its employees or owners will be respon-
sible for:
1. Knowledge of the subsurface conditions without extensive geotechnical data obtained from onsite drilling and testing of the
recovered samples,
2. Knowledge of cracks, vertical differential displacement of floors without uncovering of the floor by the client; and
3. Any other element such as joists or beams and other structural members that is boxed or otherwise not readily available to
CE for viewing, and releases CE from any liability attributable to such knowledge or conditions.
Any prescribed repair or maintenance plan detailed by this report is based on observations of apparent performance of the facility
at the time of this structural survey. Compliance with any code or specification other than as expressly noted is specifically
excluded.
The provided Floor Elevation Map and resulting recommendations are based on conditions as they now exist and DOES NOT
IMPLY OR WARRANT THAT OTHER PROBLEMS AND OR AREAS MAY NOT MANIFEST IN THE FUTURE.
This report was prepared expressly for the client and expressly for the purposes indicated by the client. Permission for use by
any other person for any purpose, or by the client for different purpose is denied unless otherwise stated in writing by CE.
CE SHALL HAVE NO LIABILITY FOR ACTS OR OMISSIONS BY THE CONTRACTOR OR HIS SUBCONTRACTORS
PERFORMING WORK ON THIS PROJECT, OR THE FAILURE OF THE CONTRACTOR TO PERFORM THE WORK IN
ACCORDANCE WITH THE REPAIR PLAN. CE IS NOT RESPONSIBLE FOR THE CONSTRUCTION MEANS, METH-
ODS, TECHNIQUES, SEQUENCE OR PROCEDURES OR THE PRECAUTIONS INCIDENTAL THERETO.
CE expressly DISCLAIMS ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE and the client expressly dis-
claims that it has contracted for or received any warranty of fitness for a particular purpose with respect to this report. THE
REPORT UNDER THIS AGREEMENT IS THE OPINION OF CE AND THERE ARE NO WARRANTIES THAT EXTEND
BEYOND THE DESCRIPTION ON THE FACE OF THIS AGREEMENT.
Page 4 of 6- Date: 7/3/2019