Loading...
HomeMy WebLinkAboutSFRA2018-4207 �L-IVV01 �R�'r DATE OF ISSUANCE: PERMIT#:_is/-4aD7 \� BUILDING PERMIT APPLICATION � � IPLEA9E PRLti'C LEGIBLY—COhiPLE'fE ENTIRE FORM) JOB ADDRESS: 1224 Berkley Dr SUITE# LOT: BLOCK: SUBDIVISION: BUILDING CONTRACTOR(company name): Steady House CURRENT MAILING ADDRESS: 15625 Witt PI CITY/STATE/ZIP: Addison Ts 75001 PH:# 2148866857 Fax# PROPERTY OWNER: Michael Cooper CURRENT MAILING ADDRESS: 1224 Berldey Dr CITY/STATE/ZIP: Grapevine TX 76051 PHONE NUMBER: PROJECT VALUE: $ 4,000.00 FIRE SPRINKLERED? YES NO s WHAT TRADES WILL BE NEEDED?(Cheek ones that apply)ELECTRIC_ PLUMBING_ MECHANICAL, DESCRIPTION OF WORK TO BE DONE: Foundation Repair 13 Piers USE OF BUILDING OR STRUCTURE: Home NAME OF BUSINESS: Total Square Footage under roof: L200 Square Footage of alteration(addition: 1300 ❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department(required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department or Licensing and Regulation for Accessibility Review. Control Number: (Not required for I &2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS.ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY,AND THAT THE DESIGN'PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINXNG SUCH APPROVAL APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: Philip Waldeck SIGNATURE _ PHONE#: 2148866857 EMAIL: ❑ CHECK BOX IF PREFERRED TO BE CONTACTED BYE:MAIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction Type: \J13 Permit Valuation: $ 4voo•00 Setbacks Approval to Issue Occupancy Group: R- Fire Sprinkler: YES — NO — Front: , Electrical — Division: Building Depth: — Left: — Plumbing — Zoning: •7 ',S' Building Width: — Rear: — Mechanical — Occupancy Load: Right: — Plan Review Approval: Date: -14,1 rd Building Permit Fee: aJ5 Site Plan Approval: Date: Plan Review Fee: Fire Department: Date: Lot Drainage Fee: Public Works Department: Date: Sewer Availability Rate: Healtb Department: Date: Water Availability Rate: Approved for Permit: Date: 11 1 N 1 Total Fees: G Lot Drainage Submitted: Approved: Total Amount Due: P.O.BOX"106,09APEVI E X76M(81i)610d165 OaORR651JBPEPIAITAPPLICAiIONB l.4Rp..:1g1,5p6,E/0],11N9,Gi1 � N 0 � Nlk N Z r4N en 3 ids :t 1ylk k � " cl =I u r � e, � O u h Q m L----------- ' i V] sr �n y L Y�f J c d w Q v: a o 5 y C N . u U C •._ t3 G to 7— � /] N CO 40 � O ,ai S � N ., a _l 7z 1.: CL c CL a. > n eq con %A CD X x J CZ ca 7 -2 W O an .. r U p 7 a Ot Q a � n. � PAL Engineering Services, Inc.ALL C H A tr F-_ REQUitR CONSULTING ENGINEERS, STRUCTURAL, MECHAZ 315 Farrar Road, Waxahachie, Texas 75165 r'f 1_ � g4` , D P L' N S Tel: (972)'�.68-4140 Fax: (972)935-0184 Registration-F-8132 fi,PPFi ut`,,`;Pl} 'L AN S HAi.!_ PE CAL COfdTRACTCR S?-IA.LI_ fUEPT ,! ,i v ;C'1 L. AT ALL T:,-` ' �=t��`i r� Foundation Inspection t!Vhvf her 5 2018 Steadv Horse Foundation Repair INSPEC;TiOl''S: Mr. Philip Waldeck 4 1 C1-r 10 Tel: 214-886-6857 ......,:.t,.. .f,.<.=;..,..,,. Email: COIJTPAC.;?C?F; Referenced Residence: Re.: Structural foundation inspection of the house at 1224 Berkley Drive,Grapevine,Texas 76051. Per your request, illy representative or I have made a visual inspection of the referenced property. The purpose of this inspection was to verify the structural integrity of the structure foundation of the referenced structure. The following are my on-site observations: ON-SITE OBSERVATIONS; The subject structure is a two-story, brick,single family residence,with a slab on grade foundation. The foundation along the perimeter of the residence has experienced a measurable amount of differential settlement and lateral movement, evidenced by- cracking in the exterior concrete, veneer and some slope in the floor.This can be repaired with the addition of exterior pressed concrete piers below the foundation. Perimeter of the foundation beam and interior floor area is to be re-leveled and stabilized to the best possible original elevation. Use steel shims for re-leveling. Also, improve drainage around perimeter. All work to meet or exceed the intent or the 2012 IRC building codes. Current elevations provided by the contractor. After all repairs are completed, I recommend the homeowner have the plumbing and drains checked by a licensed/bonded plumber and have the results forwarded to the engineer. If the homeowner would like the floors to be closer to level,Arden or a two-part, high strength, self- leveling epoxy can be used for fine leveling. Repair all interior and exterior cracks so they do not get worse. I recommend the homeowner follow the enclosed Foundation Maintenance Program. Disclaimer: This inspection consisted of visual observations only. The inspection excluded electrical,architectural, framing, mechanical,termites,wood destroying insects, sidewalk, driveway, back patio, pool.and detached structures. No performance warranty of any kind is expressed or implied. Due to the soil type in the area.the foundation may experience rrtoventenUsettlement in the future. The structure is in the condition consistent with a residential building of its age and one that has been subject to a measurable amount of foundation damage. If the local, city, county, state, federal, or any applicable code is more stringent than this report and sketch, then the code requirement overrules and takes precedent. Limit of liability shall be the fee paid for this report.® Sincerely, PFFICE COPY ;* ` ` *t xt N ` . , i ....:..... .. .. .G=.JR, f rz tit ;,•., 0 7 555 . ...`,� Lee Charles Ya•e, P.E. T6155 +tt��fi^ 4-n`Eo ,\�J,' PAL Engineering Services, Inc. #F-8132 � d `�at'D ? /o7a?7 i��/�t /�-� ' /'L2fCe�✓